2012
DOI: 10.1016/j.spinee.2012.03.034
|View full text |Cite
|
Sign up to set email alerts
|

Association between degenerative spondylolisthesis and spinous process fracture after interspinous process spacer surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
30
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(32 citation statements)
references
References 7 publications
1
30
0
Order By: Relevance
“…They reported the fracture of spinous processes in 3 of 13 patients and suggested possible causes of fracture, including the degree of osteoporosis and over-distraction of the interspinous space with an oversized implant. Kim et al 8 reported a high rate (52%) of spinous process fracture associated with ISP surgery performed in 39 patients at their institution. One of the main reasons for spinous process fracture would be the stress concentration at the bone after ISP implantation.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…They reported the fracture of spinous processes in 3 of 13 patients and suggested possible causes of fracture, including the degree of osteoporosis and over-distraction of the interspinous space with an oversized implant. Kim et al 8 reported a high rate (52%) of spinous process fracture associated with ISP surgery performed in 39 patients at their institution. One of the main reasons for spinous process fracture would be the stress concentration at the bone after ISP implantation.…”
Section: Discussionmentioning
confidence: 99%
“…Although spinous processes may be strong enough to withstand the stresses after implantation, 23 ISP devices may cause gradual erosion at the bone-implant interface under constant stress and motion, thereby increasing the recurrence probability of preoperative symptoms. In addition, the success rate of the outcome of lumbar treatment with an ISP device also depends largely on the bone density 8 and overall lumbar scoliosis 19 of patients. Like any other numerical study, this study has certain limitations.…”
Section: Discussionmentioning
confidence: 99%
“…Because the role of the LSP in pathogenesis of low back pain remains unclear, the findings of our study may have valuable clinical implications. Recently, ISPD have been used as an alternative solution to the conventional decompressive surgery for DDD, lumbar spinal stenosis caused by degenerative lumbar spondylolisthesis (DLS) [27,28]. Promising clinical outcomes have been reported.…”
Section: Discussionmentioning
confidence: 99%
“…However, there are also studies reporting that the interspinous implants may result in complications, including implant migration and spinous process fracture [4,27,28]. Kim et al [27,29] indicated that degenerative lumbar spondylolisthesis appears strongly associated with the occurrence of spinous process fracture after interspinous process spacer (IPS) surgery. Current kinematic studies indicate that for elderly patients with Grade 1 DLS, not only the shortest ISP distance but also the range of the shortest ISP distance change decreased during active in vivo function of the body.…”
Section: Discussionmentioning
confidence: 99%
“…The selection of an interspinous fusion spacer as a suitable option needs to be carefully evaluated since the incidence of complications may be associated with the device's indication. For example, Kim et al 9 observed an association between spinous process fracture recurrence and degenerative spondylolisthesis. Even though their study included 2 dynamic spacers (X-STOP Titanium, X-STOP polyaryletheretherketone) and 1 interspinous fusion device (Aspen), an association between fractures and device design could not be established; however, this study only included 8 patients treated with the interspinous fusion device (of 38 patients total), which limits the analysis of dynamic versus fusion devices.…”
Section: Clinical Complications Of Interspinous Spacersmentioning
confidence: 99%