Background: The sacroiliac joints (SIJs), the largest axial joints in the body, sit in between the sacrum and pelvic bones on either side. They connect the spine to the pelvis and thus facilitate load transfer from the lumbar spine to the lower extremities. The majority of low back pain (LBP) is perceived to originate from the lumbar spine; however, another likely source of LBP that is mostly overlooked is the SIJ. This study (Parts I and II) aims to evaluate the clinical and biomechanical literature to understand the anatomy, biomechanics, sexual dimorphism, and causes and mechanics of pain of the SIJ leading to conservative and surgical treatment options using instrumentation. Part II concludes with the mechanics of the devices used in minimal surgical procedures for the SIJ. Methods: A thorough review of the literature was performed to analyze studies related to normal SIJ mechanics, as well as the effects of sex and pain on SIJ mechanics. Results: A total of 65 studies were selected related to anatomy, biomechanical function of the SIJ, and structures that surround the joints. These studies discussed the effects of various parameters, gender, and existence of common physiological disorders on the biomechanics of the SIJ. Conclusions: The SIJ lies between the sacrum and the ilium and connects the spine to the pelvic bones. The SIJ transfers large bending moments and compression loads to lower extremities. However, the joint does not have as much stability of its own against the shear loads but resists shear due the tight wedging of the sacrum between hip bones on either side and the band of ligaments spanning the sacrum and the hip bones. Due to these, sacrum does not exhibit much motion with respect to the ilium. The SIJ range of motion in flexion-extension is about 38, followed by axial rotation (about 1.58), and lateral bending (about 0.88). The sacrum of the female pelvis is wider, more uneven, less curved, and more backward tilted, compared to the male sacrum. Moreover, women exhibit higher mobility, stresses/loads, and pelvis ligament strains compared to male SIJs. Sacroiliac pain can be due to, but not limited to, hypo-or hypermobility, extraneous compression or shearing forces, micro-or macro-fractures, soft tissue injury, inflammation, pregnancy, adjacent segment disease, leg length discrepancy, and prior lumbar fusion. These effects are well discussed in this review. This review leads to Part II, in which the literature on mechanics of the treatment options is reviewed and synthesized.
The finite element model has been used as an effective tool in human spine biomechanics. Biomechanical finite element models have provided basic insights into the workings of the cervical spine system. Advancements in numerical methods during the last decade have enabled researchers to propose more accurate models of the cervical spine. The new finite element model of the cervical spine considers the accurate representation of each tissue regarding the geometry and material. The aim of this paper is to address the new advancements in the finite element model of the human cervical spine. The procedures for creating a finite element model are introduced, including geometric construction, material-property assignment, boundary conditions and validation. The most recent and published finite element models of the cervical spine are reviewed. KEywoRds: Finite element modelling, Cervical spine, Numerical method ÖZSonlu eleman yöntemi efektif bir araç olarak omurga biyomekaniğinde yaygın kullanılmaktadır. Servikal omurga içerisinde meydana gelebilecek biyomekanik değişimlerin incelenmesine fırsat verebilmektedir. Geçtiğimiz on yıl içerisinde, geliştirilmiş olan nümerik metodlar sayesinde, daha gerçekçi omurga modellerinin çıkarılması sağlanmıştır. Günümüzde, servikal omurga modellerinde kullanılan geometri ve malzeme özellikleri olabildiğince gerçeğe yakın oluşturulabilmektedir. Bu makalenin amacı, sonlu eleman yöntemi kullanılarak insan servikal modellinin oluşturulmasını örneklerle açıklamaktır. Servikal omurga modelinin sonlu eleman yöntemi ile oluşturulmasının her bir adımı detaylı ele alınmıştır. Literatürde en son yayınlanan servikal omurga sonlu eleman modelleri incelenmiş ve karşılaştırılmıştır.
Pedicle screw-based dynamic constructs either benefit from a dynamic (flexible) interconnecting rod or a dynamic (hinged) screw. Both types of systems have been reported in the literature. However, reports where the dynamic system is composed of two dynamic components, i.e. a dynamic (hinged) screw and a dynamic rod, are sparse. In this study, the biomechanical characteristics of a novel pedicle screw-based dynamic stabilisation system were investigated and compared with equivalent rigid and semi-rigid systems using in vitro testing and finite element modelling analysis. All stabilisation systems restored stability after decompression. A significant decrease in the range of motion was observed for the rigid system in all loadings. In the semi-rigid construct the range of motion was significantly less than the intact in extension, lateral bending and axial rotation loadings. There were no significant differences in motion between the intact spine and the spine treated with the dynamic system (P>0.05). The peak stress in screws was decreased when the stabilisation construct was equipped with dynamic rod and/or dynamic screws.
Background: Fixation is one of the most common surgical techniques for the treatment of chronic pain originating from the sacroiliac joint (SIJ). Many studies have investigated the clinical outcomes and biomechanics of various SIJ surgical procedures. However, the biomechanical literature points to several issues that need to be further explored, especially for the devices used in minimally invasive surgery of the SIJ. This study (part II) aims to assess biomechanical literature to understand the existing information as it relates to efficacies of the surgical techniques and the gaps in the knowledge base. Part I reviewed basic anatomy and mechanics of the SIJ joint, including difference between males and females, and causes of pain emanating from these joints. Methods: A thorough literature review was performed pertaining to studies related to SIJ fixation techniques and the biomechanical outcomes of the surgical procedures. Results: Fifty-five studies matched the search criteria and were considered for the review. These articles predominantly pertained to the biomechanical outcomes of the minimally invasive surgery with different instrumentation systems and surgical settings. Conclusions: The SIJ is one of the most overlooked sources of lower back pain. The joint is responsible for the pain in 15% to 30% of people suffering from lower back pain. Various studies have investigated the clinical outcomes of different surgical procedures intended to improve the pain and quality of life following surgery. The data show that these techniques are indeed effective. However, clinical studies have raised several issues, like optimal number and positioning of implants, unilateral versus bilateral placements, adjacent segment disease, implant designs, and optimal location of implants with respect to variations in bone density across the SIJ. Biomechanical studies using in vitro and in silico techniques have addressed some of these issues. Studies also point out the need for additional investigations for a better understanding of the underlying mechanics for the improved long-term surgical outcomes. Further long-term clinical follow-ups are essential as well. This review presents pertinent findings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.