11th International Symposium on High-Voltage Engineering (ISH 99) 1999
DOI: 10.1049/cp:19990891
|View full text |Cite
|
Sign up to set email alerts
|

Application of the CIGRE-sensitivity verification for UHF PD detection in three-phase GIS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Partial discharge (PD) detection is the most effective method to monitor and diagnose the insulation condition of high voltage apparatus [1][2][3][4][5][6][7][8]. PD detection method is of importance among the various diagnostic techniques, since it is non-destructive, non-intrusive and can qualitatively describe the integrity of insulation system.One of the promising PD diagnostic techniques is the ultrahigh frequency (UHF) electromagnetic wave detection method that has been widely used for measuring insulation performance in gas-insulated switchgear (GIS) due to its advantageous characteristics, such as high sensitivity, wide detection range and less external disturbances [9][10][11][12][13][14][15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…Partial discharge (PD) detection is the most effective method to monitor and diagnose the insulation condition of high voltage apparatus [1][2][3][4][5][6][7][8]. PD detection method is of importance among the various diagnostic techniques, since it is non-destructive, non-intrusive and can qualitatively describe the integrity of insulation system.One of the promising PD diagnostic techniques is the ultrahigh frequency (UHF) electromagnetic wave detection method that has been widely used for measuring insulation performance in gas-insulated switchgear (GIS) due to its advantageous characteristics, such as high sensitivity, wide detection range and less external disturbances [9][10][11][12][13][14][15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…The studies of UHF partial discharge detection technique mainly concentrate on the following aspects: sensor design、optimization and calibration [3][4][5][6][7] , UHF radiation and propagation mechanism, PD source characterization [14] and fault location [15] . In addition, some researchers use UHF method as an anti-interference tool for the conventional technique.…”
Section: Introductionmentioning
confidence: 99%