2013
DOI: 10.1007/s12161-013-9563-2
|View full text |Cite
|
Sign up to set email alerts
|

Application of Graphene-based Solid-Phase Extraction Coupled with Ultra High-performance Liquid Chromatography-Tandem Mass Spectrometry for Determination of Macrolides in Fish Tissues

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 37 publications
0
9
0
Order By: Relevance
“…The developed SPE-GO-MPPS isolated metal ions from complex matrices with less interference. Excellent sensitivity (145)(146)(147)(148)(149)(150)(151)(152)(153)(154)(155)(156)(157)(158)(159)(160)(161)(162) ng L -1 ), great enrichment factor (325), and good recovery (99-103%) were obtained. Selectivity was considered in the presence of various coexisting ions with > 90% extraction recovery.…”
Section: Applications Of Graphene-based Spe In Biological Sample Analmentioning
confidence: 94%
“…The developed SPE-GO-MPPS isolated metal ions from complex matrices with less interference. Excellent sensitivity (145)(146)(147)(148)(149)(150)(151)(152)(153)(154)(155)(156)(157)(158)(159)(160)(161)(162) ng L -1 ), great enrichment factor (325), and good recovery (99-103%) were obtained. Selectivity was considered in the presence of various coexisting ions with > 90% extraction recovery.…”
Section: Applications Of Graphene-based Spe In Biological Sample Analmentioning
confidence: 94%
“…Regarding the mass spectrometry conditions, the selection of the precursor and product ion was first carried out by direct infusion of As a common additive reagent, formic acid is often included in the mobile phase to provide protons and yield improved ionization efficiency. 20 The results revealed that 0.1% formic acid will increase the MS response and improve the peak shape, while a formic acid content that is too high has no obvious effect. Consequently, ACN containing 0.1% formic acid was used as the optimal organic phase.…”
Section: Chromatography and Mass Spectrometrymentioning
confidence: 94%
“…On basis of the characteristics of alkalescence and lipophilic molecules, various solvents were applied to the extraction of macrolide compounds. The common solvents such as methanol (Wu et al, 2013), acetonitrile (Błądek, Posyniak, Gajda, Gbylik, & Żmudzki, 2012), Tris buffer (Dubois, Fluchard, Sior, & Delahaut, 2001), phosphate buffer solution (García-Mayor, Garcinuño, Fernández-Hernando, & Durand-Alegría, 2006) or ethyl acetate (Wang et al, 2014) were reported. In this study, the extraction efficiency of three extraction solvents including methanol, acetonitrile and ethyl acetate was compared.…”
Section: Extractionmentioning
confidence: 99%