2020
DOI: 10.1002/etc.4837
|View full text |Cite
|
Sign up to set email alerts
|

Application of Dispersive Liquid–Liquid Microextraction Followed by High‐Performance Liquid Chromatography/Tandem Mass Spectrometry Analysis to Determine Tetrabromobisphenol A in Complex Matrices

Abstract: An accurate and sensitive ultrasound-dispersive liquid-liquid microextraction technique followed by highperformance liquid chromatography separation coupled with electrospray ionization tandem mass spectrometry detection method to determine the presence of tetrabromobisphenol A (TBBPA) in complex environmental matrices is proposed. The miniaturized procedure was used to extract and quantify the analyte in domestic sewage, anaerobic sludge, and the aquatic test organism species Daphnia magna and Chironomus sanc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 67 publications
(92 reference statements)
0
4
0
1
Order By: Relevance
“…The developed method had a good recovery rate (88.9%) [ 142 ]. HPLC-MS/MS coupled with electrospray ionization tandem mass spectrometry was employed to detect TBBPA in complex environmental samples, the limit of detection obtained in anaerobic sludge was 2 ng/g [ 143 ]. MC-LLME was utilized to analyze TBBPA and bisphenol A (BPA) in water samples with no dispersants [ 144 ].…”
Section: Emerging Methods For Tetrabromobisphenol a Detection And Tre...mentioning
confidence: 99%
“…The developed method had a good recovery rate (88.9%) [ 142 ]. HPLC-MS/MS coupled with electrospray ionization tandem mass spectrometry was employed to detect TBBPA in complex environmental samples, the limit of detection obtained in anaerobic sludge was 2 ng/g [ 143 ]. MC-LLME was utilized to analyze TBBPA and bisphenol A (BPA) in water samples with no dispersants [ 144 ].…”
Section: Emerging Methods For Tetrabromobisphenol a Detection And Tre...mentioning
confidence: 99%
“…Tandem mass spectrometric analysis was performed using a 5500 QTRAP hybrid mass spectrometer (ABSciex) equipped with a TurboV™ ion source, operated in the negative electrospray mode (ESI-). Details on the sample preparation, extraction procedure, analytical conditions, and ESI-MS parameters have been described elsewhere (Macêdo et al, 2020). Samples were collected, filtered in combi syringe filters with a coarse glass fiber prefilter and a small-pore membrane as the main filter (polytetrafluoroethylene) (1.0/0.20 μm), and analysed on the same day.…”
Section: Chemicals and Analytical Methodsmentioning
confidence: 99%
“…The preparation of solutions of the standard sample of praziquantel for the construction of the calibration graph was done according to the following procedure. Stock solution: on an analytical balance, about 0.1 g (exact weighed) of a standard sample of praziquantel was weighed on an analytical balance, the weighed portion was transferred into a 100 ml volumetric flask, 50 ml of the mobile phase was added, thoroughly mixed until complete dissolution, after which the volume the solution was brought to the mark with the mobile phase [10]. The resulting solution had a concentration of 1000 μg praziquantel / ml.…”
Section: Fig 2 Praziquantel Analytical Standardmentioning
confidence: 99%
“…The HPLC-FLD method was used to determine ivermectin in organs and tissues [10]. The method for the determination of ivermectin in organs and tissues is based on homogenization of organ and tissue samples, selective extraction from homogenates with ethyl acetate, derivatization, isocratic elution using a Luna C18 (2) chromatographic column (100 Å, 5 µm) and fluorescence detection at λex.…”
Section: Fig 2 Praziquantel Analytical Standardmentioning
confidence: 99%