2013
DOI: 10.1016/j.ophtha.2012.12.006
|View full text |Cite
|
Sign up to set email alerts
|

Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: Measuring Peripheral Anterior Synechia in Glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
43
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 64 publications
(45 citation statements)
references
References 10 publications
1
43
0
1
Order By: Relevance
“…Fourier-domain optical coherence tomography (FD-OCT) provides noncontact, quantitative measurements of the anterior chamber angle (ACA), and the examination is fast and well-tolerated. 5 In addition, FD-OCT captures high-resolution images of the microanatomic structure of the anterior chamber and may allow longitudinal comparisons to established baselines. Evaluation of angle-closure suspects by OCT has proved valuable in the early diagnosis and prevention of PACG.…”
mentioning
confidence: 99%
“…Fourier-domain optical coherence tomography (FD-OCT) provides noncontact, quantitative measurements of the anterior chamber angle (ACA), and the examination is fast and well-tolerated. 5 In addition, FD-OCT captures high-resolution images of the microanatomic structure of the anterior chamber and may allow longitudinal comparisons to established baselines. Evaluation of angle-closure suspects by OCT has proved valuable in the early diagnosis and prevention of PACG.…”
mentioning
confidence: 99%
“…With the development of anterior segment optical coherence tomography (AS-OCT), it is possible to image the anterior chamber and angles in a cross section 11 12. More recently, Lai and associates have reported the use of swept-source OCT (SS-OCT) for imaging and quantifying PAS 13. This latter modality has the advantage over AS-OCT in allowing circumferential assessment of the anterior chamber angles by simultaneously obtaining 128 cross-sectional radial scans across the anterior chamber at equal intervals (every 1.4°).…”
mentioning
confidence: 99%
“…First, the resolution of retrocorneally attached tissue was limited in some dense corneal leukoma cases due to the low penetration depth of the 830 nm SD-OCT laser. Swept-source OCT allows for visualisation and reproducible measurements of the anterior segment of the eye;39 however, we still lack longer-wavelength OCT systems that would enable deeper penetration. Second, because this was a non-randomised study, surgeons knew before surgery that they would use OCT. A bias towards reducing intervention aggressiveness may therefore have affected the results.…”
Section: Discussionmentioning
confidence: 99%