An In Vitro Human Lens Capsular Bag Model Adopting a Graded Culture Regime to Assess Putative Impact of IOLs on PCO Formation

Abstract: Wormstone IM. An in vitro human lens capsular bag model adopting a graded culture regime to assess putative impact of IOLs on PCO formation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
37
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(41 citation statements)
references
References 19 publications
3
37
0
Order By: Relevance
“…In addition, cells are less likely to populate the IOL surface of the Vivinex IOL than the AcrySof IOL, which further reduces light scatter following surgery. 36 Two other disadvantages of hydrophobic acrylic IOLs are more frequent dysphotopsias related to a low anterior curvature and a high refractive index and the development of glistenings: microvacuoles within the IOL material may occur when the IOL is in an aqueous environment and water fills microscopic openings within the material. Typical for acrylic IOLs, glistenings appear as white sparkling areas all over the IOL optic, which may impair the optical quality.…”
Section: Three Years Postoperatively the Vivinex Xy1 Iolsmentioning
confidence: 99%
“…In addition, cells are less likely to populate the IOL surface of the Vivinex IOL than the AcrySof IOL, which further reduces light scatter following surgery. 36 Two other disadvantages of hydrophobic acrylic IOLs are more frequent dysphotopsias related to a low anterior curvature and a high refractive index and the development of glistenings: microvacuoles within the IOL material may occur when the IOL is in an aqueous environment and water fills microscopic openings within the material. Typical for acrylic IOLs, glistenings appear as white sparkling areas all over the IOL optic, which may impair the optical quality.…”
Section: Three Years Postoperatively the Vivinex Xy1 Iolsmentioning
confidence: 99%
“…37 In addition, a graded culture regime for the in vitro human lens capsular bag model that better reflects the clinical events following cataract surgery should be established in future studies. 38 Due to the in vitro character of this study, further studies have to determine whether the short and early release of gefitinib by the IOL is sufficient to decelerate PCO formation longer-term.…”
Section: Discussionmentioning
confidence: 99%
“…With the addition of SIS3, the staining of E-cadherin did not alter in comparison to the untreated control explants and only a partial reduction in β-catenin nuclear translocation was seen. Ex vivo models have also been used to improve the reproduction of the clinical environment of PCO as shown by Eldred [123] who used a graded culture media in a human capsular bag model to assess the impact of IOL design on its propensity to initiate PCO development. Mock surgeries were completed on donor human eye tissue after which the eyes were implanted with either Hoya Vivinex or Alcon Acrysof lenses.…”
Section: Ex Vivo Modelsmentioning