2002
DOI: 10.1109/mper.2002.4311669
|View full text |Cite
|
Sign up to set email alerts
|

An Evaluation of Model-Based Stator Resistance Estimation for Induction Motor Stator Winding Temperature Monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
43
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(46 citation statements)
references
References 0 publications
0
43
0
Order By: Relevance
“…If the incipient inter-turn fault is not monitored or the corresponding measures are not implemented in a timely manner, the more serious phase-to-phase or turn-to-ground fault may emerge [37]. At present, the practical monitoring methods for the inter-turn short-circuit fault are classified into the following five types: 1) Methods based on temperature signal analysis The continuous monitoring of temperature signals can facilitate the observation of the winding insulation in the DD-WT and the condition of the wind turbine [25][26][27][28][29]. When the temperature in the DD-WT exceeds a certain value, the DD-WT must be shut down for maintenance.…”
Section: Condition Monitoring Of Stators Of Pmsgsmentioning
confidence: 99%
See 1 more Smart Citation
“…If the incipient inter-turn fault is not monitored or the corresponding measures are not implemented in a timely manner, the more serious phase-to-phase or turn-to-ground fault may emerge [37]. At present, the practical monitoring methods for the inter-turn short-circuit fault are classified into the following five types: 1) Methods based on temperature signal analysis The continuous monitoring of temperature signals can facilitate the observation of the winding insulation in the DD-WT and the condition of the wind turbine [25][26][27][28][29]. When the temperature in the DD-WT exceeds a certain value, the DD-WT must be shut down for maintenance.…”
Section: Condition Monitoring Of Stators Of Pmsgsmentioning
confidence: 99%
“…Temperature signal analysis [25][26][27][28][29][30] Monitoring of inter-turn short-circuit fault and phase-to-ground insulation deterioration…”
Section: Condition Monitoring Of Stators Of Pmsgsmentioning
confidence: 99%
“…According the literature [11][12][13][14][15], we can distinguish two types of electrical machines thermal modeling approaches:…”
Section: Introductionmentioning
confidence: 99%
“…The value of R S can be calculated from the voltage drop R S i S , derived from fundamental components of U S and I S [6], but this requires a thorough knowledge of the remaining PMSM parameters and fails in all cases where R S i S << U n , which is the case in all large power drives. The alternative approach is the test signal injection [7] which operates at test frequencies decoupled from the fundamental, thus eliminating the sensitivity of the R S estimate to the PMSM operating regime or to variation of the remaining parameters.…”
Section: Introductionmentioning
confidence: 99%