1999
DOI: 10.1088/0031-9155/44/5/001
|View full text |Cite
|
Sign up to set email alerts
|

An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry

Abstract: Epoxy resin phantom materials have been available for some time and are widely used for dosimetry purposes, not least in audit phantoms. Information on their behaviour is partly available in the literature, but there are different mixes and formulations often given similar names and it may not be appropriate to transfer information from one material to another. Five commercially available water substitute materials have been evaluated for use in megavoltage photon beams: WT1, WTe, RMI 451, RMI 457 and 'plastic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 9 publications
1
18
0
Order By: Relevance
“…The agreement was in most cases within 1% and a maximum deviation of 1.5%. This level of agreement between doses measured in solid phantoms and in water is similar to previous work using megavoltage X-ray beams (Allahverdi et al, 1999;Liu et al, 2003) and in Monte Carlo calculations at similar photon energies for brachytherapy sources (Meigooni et al, 1994). The transmission values through Perspex are less than those for water and with a greater deviation, being up to 4% at depth.…”
Section: Resultssupporting
confidence: 87%
See 2 more Smart Citations
“…The agreement was in most cases within 1% and a maximum deviation of 1.5%. This level of agreement between doses measured in solid phantoms and in water is similar to previous work using megavoltage X-ray beams (Allahverdi et al, 1999;Liu et al, 2003) and in Monte Carlo calculations at similar photon energies for brachytherapy sources (Meigooni et al, 1994). The transmission values through Perspex are less than those for water and with a greater deviation, being up to 4% at depth.…”
Section: Resultssupporting
confidence: 87%
“…One aspect of the solid phantoms that will contribute to uncertainties in the transmission measurements is the inhomogeneity in the manufacture of the blocks, leading to variations in density (Allahverdi et al, 1999;Seuntjens et al, 2005). The results indicate that within the uncertainties, the Plastic Water, RMI-457 Solid Water and RW3 phantom materials meet the ICRU requirements for water equivalency at this particular energy.…”
Section: Resultsmentioning
confidence: 86%
See 1 more Smart Citation
“…1b). Here, Allahverdi et al [9] reported that the SW phantom is suitable for relative dosimetry in megavoltage photon beams, and difference of up to 1% is observed for absolute measurements. For angular dependence measurements, we used a cylindrical PMMA phantom with a radius of 8.0 cm as shown in Fig.…”
Section: Experimental Apparatusmentioning
confidence: 86%
“…When commissioned in a 6 MV photon beam, the percent depth dose measured with an ionisation chamber was compared to measurements in water and a maximum difference of 1.1 % was observed at a depth of 26 cm. More rigorous testing by Tello et al [17] and Allahverdi et al [18] have quantified agreement at this beam quality to within 0.5 %.…”
Section: Integrated Pixel Value (Ipv)mentioning
confidence: 77%