Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented.
A range of liquids suitable as quality control test objects for measuring the accuracy of clinical MRI diffusion sequences (both apparent diffusion coefficient and tensor) has been identified and characterized. The self-diffusion coefficients for 15 liquids (3 cyclic alkanes: cyclohexane to cyclooctane, 9 n-alkanes: n-octane to n-hexadecane, and 3 n-alcohols: ethanol to 1-propanol) were measured at 15-30°C using an NMR spectrometer. Values at 22°C range from 0.36 to 2.2 10 ؊9 m 2 s ؊1 . Typical 95% confidence limits are ؎2%. Temperature coefficients are 1.7-3.2 %/°C. T 1 and T 2 values at 1.5 T and proton density are given. n-tridecane has a diffusion coefficient close to that of normal white matter. The longer n-alkanes may be useful T 2 standards. Measurements from a spin-echo MRI sequence agreed to within 2%. Magn Reson Med 43:368 -374, 2000.
In polymer gel dosimetry using magnetic resonance imaging, the uncertainty in absorbed dose is dependent on the experimental determination of T2. The concept of dose resolution (Dpdelta) of polymer gel dosimeters is developed and applied to the uncertainty in dose related to the uncertainty in T2 from a range of T4 encountered in polymer gel dosimetry. Dpdelta is defined as the minimal separation between two absorbed doses such that they may be distinguished with a given level of confidence, p. The minimum detectable dose (MDD) is Dpdelta as the dose approaches zero. Dpdelta and the minimum detectable dose both give a quantifiable indication of the likely practical limitations and usefulness of the dosimeter. Dpdelta of a polyacrylamide polymer gel dosimeter is presented for customized 32-echo and standard multiple-spin-echo sequences on a clinical MRI scanner. In evaluating uncertainties in T2, a parameter of particular significance in the pulse sequence is the echo spacing (ES). For optimal results, ES should be selected to minimize Dpdelta over a range of doses of interest in polymer gel dosimetry.
Polymer gel dosimeters offer a wide range of potential applications in the three-dimensional verification of complex dose distribution such as in intensity-modulated radiotherapy (IMRT). Until now, however, polymer gel dosimeters have not been widely used in the clinic. One of the reasons is that they are difficult to manufacture. As the polymerization in polymer gels is inhibited by oxygen, all free oxygen has to be removed from the gels. For several years this was achieved by bubbling nitrogen through the gel solutions and by filling the phantoms in a glove box that is perfused with nitrogen. Recently another gel formulation was proposed in which oxygen is bound in a metallo-organic complex thus removing the problem of oxygen inhibition. The proposed gel consists of methacrylic acid, gelatin, ascorbic acid, hydroquinone and copper(II)sulphate and is given the acronym MAGIC gel dosimeter. These gels are fabricated under normal atmospheric conditions and are therefore called 'normoxic' gel dosimeters. In this study, a chemical analysis on the MAGIC gel was performed. The composition of the gel was varied and its radiation response was evaluated. The role of different chemicals and the reaction kinetics are discussed. It was found that ascorbic acid alone was able to bind the oxygen and can thus be used as an anti-oxidant in a polymer gel dosimeter. It was also found that the anti-oxidants N-acetyl-cysteine and tetrakis(hydroxymethyl)phosphonium were effective in scavenging the oxygen. However, the rate of oxygen scavenging is dependent on the anti-oxidant and its concentration with tetrakis(hydroxymethyl)phosphonium being the most reactive anti-oxidants. Potentiometric oxygen measurements in solution provide an easy way to get a first impression on the rate of oxygen scavenging. It is shown that cupper(II)sulphate operates as a catalyst in the oxidation of ascorbic acid. We, therefore, propose some new normoxic gel formulations that have a less complicated chemical formulation than the MAGIC gel.
A simple methodology for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry is presented to enable individuals to undertake such work in a routine clinical environment. Samples of PAG were irradiated using a linear accelerator and imaged using a 0.5 T (22 MHz) Philips Gyroscan MRI scanner. The mean spin-lattice relaxation rate was measured using a 'turbo-mixed' sequence, consisting of a series of 90 degrees pulses, each followed by acquisition of a train of spin echoes. The mean sensitivity for five different batches of PAG in the range up to 10 Gy was calculated to be 0.0285 s-1 Gy-1 for the mean spin-lattice relaxation rate with a percentage standard deviation of 1.25%. The overall reproducibility between batches was calculated to be 2.69%. This methodology, which introduces the novel use of pre-filled nitrogen vials for calibration, has been used to develop techniques for filling anatomically shaped anthropomorphic phantoms.
This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage x-ray beams are used in intra operative units, within animal irradiators and in on-board imagers on linear accelerators and kilovoltage dosimetry is important in these applications as well. This review covers both reference and relative dosimetry of kilovoltage x-ray beams and provides recommendations for clinical measurements based on the literature to date. In particular, practical aspects for the selection of dosimeter and phantom material are reviewed to provide suitable advice for medical physicists. An overview is also presented of dosimeters other than ionization chambers which can be used for both relative and in vivo dosimetry. Finally, issues related to the treatment planning and the use of Monte Carlo codes for solving radiation transport problems in kilovoltage x-ray beams are presented.
Polyacrylamide gels (PAGs) are used for magnetic resonance imaging radiation dosimetry. Fourier transform (FT) Raman spectroscopy studies were undertaken to investigate cross-linking changes during the copolymerization of polyacrylamide gels in the spectral range of 200-3500 cm(-1). Vibrational bands of 1285 cm(-1) and 1256 cm(-1) were assigned to acrylamide and bis-acrylamide single CH2 deltaCH2 binding modes. Bands were found to decrease in amplitude with increasing absorbed radiation dose as a result of copolymerization. Principal component regression was performed on FT-Raman spectra of PAG samples irradiated to 50 Gy. Two components were found to be sufficient to account for 98.7% of the variance in the data. Cross validation was used to establish the absorbed radiation dose of an unknown PAG sample from the FT-Raman spectra. The calculated correlation coefficient between measured and predictive samples was 0.997 with a standard error of estimate of 0.976 and a standard error of prediction of 1.140. Results demonstrate the potential of FT-Raman spectroscopy for ionizing radiation dosimetry using polyacrylamide gels.
Changes in the linear attenuation coefficient of polymer gel dosimeters post-irradiation enable the imaging of dose distributions by x-ray computed tomography (CT). Various compositions of polymer gel dosimeters manufactured from acrylamide (AA), and N,N'-methylene-bis-acrylamide (BIS) comonomers and gelatin or agarose gelling agents were investigated. This work shows that increasing the comonomer concentration increases the CT-dose sensitivity of the polymer gel dosimeter. This can be further increased by replacing gelatin with agarose. Varying the gelatin concentration however does not significantly change the CT-dose sensitivity. Among the compositions studied, dose resolution (D(delta)95%) was found to be optimal for polymer gel dosimeters comprising 5% gelatin, 3% AA, 3% BIS and 89% water.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.