An electrochemical sensor based on a magnetic Fe3O4 nanoparticles and gold nanoparticles modified electrode for sensitive determination of trace amounts of arsenic(iii)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
24
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(27 citation statements)
references
References 29 publications
2
24
0
1
Order By: Relevance
“…For example, LODs in the range 0.01-0.05 ppb are presented in [26,[36][37][38][39][40][41][42] and LOD lower than 0.005 ppb in [43][44][45][46][47][48]. A number of different approaches have been used to improve the sensitivity of detection:…”
Section: As(iii) Determination By Anodic Stripping Voltammetry (Asv)mentioning
confidence: 99%
See 1 more Smart Citation
“…For example, LODs in the range 0.01-0.05 ppb are presented in [26,[36][37][38][39][40][41][42] and LOD lower than 0.005 ppb in [43][44][45][46][47][48]. A number of different approaches have been used to improve the sensitivity of detection:…”
Section: As(iii) Determination By Anodic Stripping Voltammetry (Asv)mentioning
confidence: 99%
“…therein] and composites (M-NPs with carbon nanotubes or graphene) with electrocatalytic and adsorption properties [28,46,[49][50][51][52][53][54][55][56][57][58][59][60][61][62][63].…”
Section: As(iii) Determination By Anodic Stripping Voltammetry (Asv)mentioning
confidence: 99%
“…70 Fig. 107 Some of other developed electrochemical sensors for the detection and determination of heavy metal ions such as Hg(II), [108][109][110][111] Cr(VI), 69,109 Pb(II), 113,114 Cd(II), 114,115 As(III) [116][117][118] and Cu(II) 119 using the nanostructured materials are listed in Table 1. The Au NPs ($10 nm in diameter) were well dispersed on the as-prepared TiO 2 NTs.…”
Section: Detection Of Heavy Metalsmentioning
confidence: 99%
“…Various methods including atomic absorption spectrometry (AAS) (Aggett and Aspell, 1976;Becker et al, 2011;Fernando et al, 2009), electrochemical methods Cui et al, 2012;Gamboa et al, 2014;Salimi et al, 2003) and high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) (Gao et al, 2009) have been reported for the detection of As(III). Recently a few colorimetric aptasensor based on aggregation of gold nanoparticles (GNPs) Zhan et al, 2014) and silver nanoparticles (SNPs) have been reported for the determination of As(III).…”
Section: Introductionmentioning
confidence: 98%