2017
DOI: 10.1016/j.microc.2017.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Advanced sensing performance towards simultaneous determination of quaternary mixture of antihypertensives using boron-doped diamond electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 40 publications
(9 citation statements)
references
References 44 publications
0
9
0
Order By: Relevance
“…). That is the reason that in many instances, when galvanostatic pretreatments are compared (for a given absolute value of the applied current density), the CPT time is chosen as a multiple of the APT time – see e. g. Ardila et al ., Lourencao et al ., Moraes et al . or Eisele et al .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…). That is the reason that in many instances, when galvanostatic pretreatments are compared (for a given absolute value of the applied current density), the CPT time is chosen as a multiple of the APT time – see e. g. Ardila et al ., Lourencao et al ., Moraes et al . or Eisele et al .…”
Section: Discussionmentioning
confidence: 99%
“…Interestingly, similarly to a CPT, in some instances an APT might also enable the simultaneous determination of different analytes due to a better separation between their peak potentials. Among the several studies listed in Table , it is worthwhile highlighting the results reported by Moraes et al . on the determination of a quaternary mixture of antihypertensives: amlodipine besylate, amiloride hydrochloride, hydrochlorothiazide, and atenolol.…”
Section: Electroanalytical Applications Of Electrochemically Pretreatmentioning
confidence: 99%
See 1 more Smart Citation
“…Analysis of authentic samples containing HCTZ and VAL showed no interference from the common additives and excipients. In addition, there are methodologies developed by other research groups for the simultaneous detection of HCTZ with enalapril, metoprolol, ramipril and with more of one pharmaceutical as described by Morais and coauthors that used AML, amiloride hydrochloride and atenolol …”
Section: Electroanalysis Of Pharmaceuticalsmentioning
confidence: 99%
“…Thus, it is an excellent material with unicast properties, which has allowed several applications in electrochemical science [20,23,24], such as degradation of organic pollutants (due to its high capacity of generated hydroxyl radical in situ) [25], photoelectrochemical CO 2 reduction [26], electrochemical sensor [15,16,19,[27][28][29] and electro-organic synthesis [30]. Furthermore, the electrochemical performance of BDDE can be modified by a cathodic or anodic pre-treatment in sulphuric acid solution, due to the possibility of changing the surface termination of BDDE; H-termination and O-termination are obtained by cathodic and anodic pretreatment, respectively [31,32].…”
Section: Introductionmentioning
confidence: 99%