2012 IEEE International Conference on Power System Technology (POWERCON) 2012
DOI: 10.1109/powercon.2012.6401449
|View full text |Cite
|
Sign up to set email alerts
|

Adaptive Frequency Control for Hybrid Wind-Diesel power system using system estimator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…In hybrid power system, the diesel generator (DG) is considered as an extra unit that provides electrical power output via a synchronous generator that is connected to the diesel engine [45]. The transfer function of DG can be described as follows [46]:…”
Section: E Diesel Generator Modelmentioning
confidence: 99%
“…In hybrid power system, the diesel generator (DG) is considered as an extra unit that provides electrical power output via a synchronous generator that is connected to the diesel engine [45]. The transfer function of DG can be described as follows [46]:…”
Section: E Diesel Generator Modelmentioning
confidence: 99%
“…Wind-diesel system has been the topic of numerous researches in the past decades and various control techniques have been proposed in literature for blade pitch control. Each method is suitable for a specific problem, depending on the nature of the control problem such as ANN (artificial neural network) [3,4], GA (genetic algorithm) [5][6][7][8], FLC (fuzzy logic control) [9][10][11][12], PSO (particle swarm optimization) [13,14], BCO (bee colony optimization) [15], BFO (bacterial foraging optimization) [16], and VSC (variable structure controllers) [17]. However, due to the fact that in wind-diesel problem each control area can have random load changes and random wind speed, many of these methods may not be useful as they require substantial amount of training based on predicted scenarios and specific system parameters such as ANN.…”
Section: David Publishingmentioning
confidence: 99%
“…K fc is chosen because it is the most sensitive parameter in the system. It means that the control response of the power system is very sensitive for K fc changes [6]. The simulation results are presented in Fig.…”
Section: Casementioning
confidence: 99%
“…In [8], performance analysis of an isolated wind-diesel hybrid power system employing permanent magnet induction generator has been presented by Sharma and Bhatti. A general simulation algorithm for the accurate assessment of isolated diesel-wind turbine systems interaction has been presented in [9]. In [10], system estimation approach for frequency control in hybrid wind-diesel power system has been studied by Supriyadi et al and, thus, the list goes so on.…”
Section: Literature Reviewmentioning
confidence: 99%