2013
DOI: 10.1016/j.apradiso.2013.09.005
|View full text |Cite
|
Sign up to set email alerts
|

Accurate determination of 41Ca concentrations in spent resins from the nuclear industry by Accelerator Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…The initial radiochemical Method 1 for the determination of 41 Ca, 55 Fe and 63 Ni was a combination of published articles [2,12,25,26]. The procedure was based on 4 h acid leaching of the solid subsample (0.5 g) using 30 ml of conc.…”
Section: Testing Of Methods 1 In Inactive Concrete and The Radiochemical Analysis Of 41 Ca 55 Fe And 63 Ni In Activated Concretementioning
confidence: 99%
“…The initial radiochemical Method 1 for the determination of 41 Ca, 55 Fe and 63 Ni was a combination of published articles [2,12,25,26]. The procedure was based on 4 h acid leaching of the solid subsample (0.5 g) using 30 ml of conc.…”
Section: Testing Of Methods 1 In Inactive Concrete and The Radiochemical Analysis Of 41 Ca 55 Fe And 63 Ni In Activated Concretementioning
confidence: 99%
“…The radiochemical methods utilised in the DTM analysis of the activated concrete have been summarised by Leskinen et al [4]. The utilised procedures were mainly based on published references [13][14][15][16][17][18][19][20][21][22][23][24][25][26][27], but also internal procedures and modifications based on discussions between the participating laboratories. The main focus was given for 3 H, 14 C, 55 Fe and 63 Ni whereas 36 Cl and 41 Ca were optional.…”
Section: Overview Of the Radiochemical Analysesmentioning
confidence: 99%
“…142 Calcium-41 has been successfully separated from the bulk matrix and radiometric interferences by numerous techniques including ion exchange, liquid-liquid extraction, liquid membrane separation, and precipitations including calcium uoride, carbonate and oxalate. 139,143,145 The long half-life of 41 Ca and low energy X-ray and Auger electrons makes it well-suited to mass spectrometric determination, with an additional interest in measurement of the 41 Ca : 40 Ca ratio in nuclear samples. There is no known ICP-MS application for detection of 41 Ca, due to signicant tailing effects from 40 Ca, as well as 40 Ar (99.60% natural abundance) in the plasma gas, with additional interferences from isobaric 41 K (natural abundance 6.73%) and instrument-generated 40 CaH.…”
Section: Calcium-41mentioning
confidence: 99%
“…RIMS is a highly sensitive technique for isotopic 41 Ca/ 40 Ca measurements in the 10 À10 to 10 À11 range, 136,139 whilst AMS is capable of isotope ratio measurements as low as 10 À15 . 139,145 Given the difficulty in routinely measuring 41 Ca, Nottoli et al (2013) estimated the activity from measurement of 60 Co in ion exchange resins used for primary uid purication in pressurized water reactors (PWR's). 145 AMS has been compared to LSC for detection of 41 Ca in concrete and other solid samples including sediment and soil.…”
Section: Calcium-41mentioning
confidence: 99%
See 1 more Smart Citation