2022
DOI: 10.1186/s12951-022-01258-3
|View full text |Cite
|
Sign up to set email alerts
|

A UCMPs@MIL-100 based thermo-sensitive molecularly imprinted fluorescence sensor for effective detection of β-lactoglobulin allergen in milk products

Abstract: In this study, a thermo-sensitive molecularly imprinted fluorescence sensor was developed for the specific detection of β-Lactoglobulin (β-LG) allergen in milk products. The metal–organic frameworks (MIL-100) with a high specific surface area was coated on the surface of upconversion micro-particles (UCMPs). As the core, an imprinted polymer layer allowing for swelling and shrinking with response to temperature was prepared, which exhibited high adsorption and mass transfer capabilities for β-LG allergen. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 39 publications
0
5
0
Order By: Relevance
“…The limit of detection (LOD) was estimated to be 9.8 × 10 –10 M based on 3σ/ s . The above lower LOD of Si-CD@CdTe@CMIP toward HVA and Al 3+ illustrated that the Si-CD@CdTe@CMIP exhibited high sensitivity for trace detection of HVA and Al 3+ . , …”
Section: Resultsmentioning
confidence: 92%
See 1 more Smart Citation
“…The limit of detection (LOD) was estimated to be 9.8 × 10 –10 M based on 3σ/ s . The above lower LOD of Si-CD@CdTe@CMIP toward HVA and Al 3+ illustrated that the Si-CD@CdTe@CMIP exhibited high sensitivity for trace detection of HVA and Al 3+ . , …”
Section: Resultsmentioning
confidence: 92%
“…The above lower LOD of Si-CD@CdTe@CMIP toward HVA and Al 3+ illustrated that the Si-CD@CdTe@CMIP exhibited high sensitivity for trace detection of HVA and Al 3+ . 27,28 In this work, the Si-CD@CdTe@CMIP for simultaneous detection of HVA and Al 3+ was further investigated, and the results are shown in Figure 2E and Figure S5E. Exposed to the mixture solution of HVA and Al 3+ , the fluorescence intensity of Si-CD@CdTe@CMIP was quenched with the addition of HVA and Al 3+ .…”
Section: Analytical Chemistrymentioning
confidence: 92%
“…The LOD of the developed assay was lower than for some of the others. [33][34][35]39,40 Its detection time was also shorter than for most of the assays. 32,[35][36][37][38][39][40] Fig.…”
Section: Sensitivitymentioning
confidence: 99%
“…[33][34][35]39,40 Its detection time was also shorter than for most of the assays. 32,[35][36][37][38][39][40] Fig. 3…”
Section: Sensitivitymentioning
confidence: 99%
“…Traditional chromatography is commonly used for β-Lg monitoring, including high performance liquid chromatography (HPLC), 10 ultra-high performance liquid chromatography (UHPLC), 11 and liquid chromatography tandem mass spectrometry (LC-MS/MS). 12 In addition, some novel detection methods, such as enzyme-linked immunosorbent assay, 13 photoelectrochemical immunoassay, 14 lateral flow immunoassay, 15 real-time quantitative polymerase chain reaction, 16 transient isotachophoresis, 17 and molecular imprinting, 18 have also been used for the detection of β-Lg. Although these reported methods have exhibited very good detection sensitivity and accuracy, there are still some disadvantages, such as the need for expensive analytical equipment and complex sample pre-treatment processes.…”
Section: Introductionmentioning