A Study of Beer Staling Using Chemiluninescence Analysis

Abstract: The chemiluninescence (CL) analysis has been used to study beer staling. Several types of commercial Japanese beers were stored at 37°C and their CL development analysed at 60°C. The CL level in beer developed as the beer was stored to reach a maximum level and then decreased. The sum of the CL intensities for the first 1 hour showed a good relationship with staling degree as assessed in mean panel scores. It is postulated that the deterioration rates of beers might be assessed from the CL producing patterns i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1991
1991
2015
2015

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 21 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…According to the chemiluminescence analysis proposed by Kaneda et al 12 , 10 mL of the beer sample, after being degassed by supersonication, was placed in a stainless steel dish (glass dish) and chemiluminescence was measured at 60°C for up to 20 h. Beer was stored at 0°C before being analysed. To record the radiated photons of the sample, a Tohoku Electronic Industrial Co. Ltd.…”
Section: Chemiluminescence Measurementmentioning
confidence: 99%
“…According to the chemiluminescence analysis proposed by Kaneda et al 12 , 10 mL of the beer sample, after being degassed by supersonication, was placed in a stainless steel dish (glass dish) and chemiluminescence was measured at 60°C for up to 20 h. Beer was stored at 0°C before being analysed. To record the radiated photons of the sample, a Tohoku Electronic Industrial Co. Ltd.…”
Section: Chemiluminescence Measurementmentioning
confidence: 99%
“…Free sulfite levels could be analyzed if an acidic solution was used for sample preparation. The detection limit of sulfite in beer using this method is 0.6 M. Most sulfites in beer are bisulfite adducts (Kaneda et al, 1991).…”
Section: Introductionmentioning
confidence: 92%
“…For comparison with this method, sulfite determination by HPLC-ECD was previously described (Kaneda et al, 1991).…”
Section: Hplc-electrochemical Detection (Ecd)mentioning
confidence: 99%
See 1 more Smart Citation
“…In order to understand the mechanism of beer ageing and to control beer flavour changes, many studies have focused on the chemical aspects of beer ageing and the main changes in components and the corresponding pathways have now been elucidated . Apart from these, there have been many studies on indices assessing beer flavour stability . Several indices have been developed, for example, the 2‐thiobarbituric acid (TBA) value, the resistance‐to‐staling value, 2,2‐diphenyl‐1‐picrylhydrazyl, TRAP (total reactive antioxidant potential) and lag time of electron spin resonance .…”
Section: Introductionmentioning
confidence: 99%