2022
DOI: 10.3390/s22030784
|View full text |Cite
|
Sign up to set email alerts
|

A Single Sacral-Mounted Inertial Measurement Unit to Estimate Peak Vertical Ground Reaction Force, Contact Time, and Flight Time in Running

Abstract: Peak vertical ground reaction force (Fz,max), contact time (tc), and flight time (tf) are key variables of running biomechanics. The gold standard method (GSM) to measure these variables is a force plate. However, a force plate is not always at hand and not very portable overground. In such situation, the vertical acceleration signal recorded by an inertial measurement unit (IMU) might be used to estimate Fz,max, tc, and tf. Hence, the first purpose of this study was to propose a method that used data recorded… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(27 citation statements)
references
References 55 publications
(101 reference statements)
0
27
0
Order By: Relevance
“…Protocols to assess validity and reliability varied greatly. Overall, studies included between five [ 27 ] and 100 [ 95 , 96 ] participants, with the average number of participants being 22 (± 18). The mean age of participants was 26.8 (± 4.5) years.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Protocols to assess validity and reliability varied greatly. Overall, studies included between five [ 27 ] and 100 [ 95 , 96 ] participants, with the average number of participants being 22 (± 18). The mean age of participants was 26.8 (± 4.5) years.…”
Section: Resultsmentioning
confidence: 99%
“…Sixty-two articles stated that they used IMUs; however, 14 of these studies only used the accelerometer capabilities within the IMU [23,24,38,52,56,57,62,[72][73][74][75][76][77][78] and 20 studies stated they used the accelerometer and gyroscope components for the data analysis [26,33,43,49,50,54,59,61,[79][80][81][82][83][84][85][86][87][88][89][90]. The remaining 27 studies either did not comment on components used [70,[91][92][93][94][95][96][97][98] or implied they used all accelerometer, gyroscope and magnetometer components for the data analysis [19-21, 28, 29, 36, 42, 99-109]. One study used an IMU and a separate one-dimensional accelerometer [61].…”
Section: Inertial Measurement Unitsmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, methods focusing on a single point have been developed [8,15]. In running, an IMU placed on the sacrum was used to predict peak vertical ground reaction force, impulse and contact time [16], but these parameters could also be determined using a traditional approach [17]. In cross country roller skiing on a treadmill, IMUs placed on the skis and poles were used to detect temporal events in classical style [18] and in skating style with IMUs placed on skis and wrist [19].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, methods focusing on a single point have been developed [ 8 , 15 ]. In running, an IMU placed on the sacrum was used to predict the peak vertical ground reaction force, impulse and contact time [ 16 ], but these parameters could also be determined using a traditional approach [ 17 ]. In cross-country roller skiing on a treadmill, IMUs placed on the skis and poles were used to detect temporal events in the classical style [ 18 ], and IMUs placed on skis and wrists were used in the skating style [ 19 ].…”
Section: Introductionmentioning
confidence: 99%