A lower duty factor (DF) reflects a greater relative contribution of leg swing versus ground contact time during the running step. Increasing time on the ground has been reported in the scientific literature to both increase and decrease the energy cost (EC) of running, with DF reported to be highly variable in runners. As increasing running speed aligns running kinematics more closely with spring-mass model behaviours and re-use of elastic energy, we compared the centre of mass (COM) displacement and EC between runners with a low (DF low ) and high (DF high ) duty factor at typical endurance running speeds. Forty well-trained runners were divided in two groups based on their mean DF measured across a range of speeds. EC was measured from 4 min treadmill runs at 10, 12 and 14 km h −1 using indirect calorimetry. Temporal characteristics and COM displacement data of the running step were recorded from 30 s treadmill runs at 10, 12, 14, 16 and 18 km h −1 . Across speeds, DF low exhibited more symmetrical patterns between braking and propulsion phases in terms of time and vertical COM displacement than DF high . DF high limited global vertical COM displacements in favour of horizontal progression during ground contact. Despite these running kinematics differences, no significant difference in EC was observed between groups. Therefore, both DF strategies seem energetically efficient at endurance running speeds.
Biomechanical parameters are often analyzed independently, although running gait is a dynamic system wherein changes in one parameter are likely to affect another. Accordingly, the Volodalen® method provides a model for classifying running patterns into 2 categories, aerial and terrestrial, using a global subjective rating scoring system. We aimed to validate the Volodalen® method by verifying whether the aerial and terrestrial patterns, defined subjectively by a running coach, were associated with distinct objectively-measured biomechanical parameters. The running patterns of 91 individuals were assessed subjectively using the Volodalen® method by an expert running coach during a 10-min running warm-up. Biomechanical parameters were measured objectively using the OptojumpNext® during a 50-m run performed at 3.3, 4.2, and 5 m·s(-1) and were compared between aerial- and terrestrial-classified subjects. Longer contact times and greater leg compression were observed in the terrestrial compared to the aerial runners. The aerial runners exhibited longer flight time, greater center of mass displacement, maximum vertical force and leg stiffness than the terrestrial ones. The subjective categorization of running patterns was associated with distinct objectively-quantified biomechanical parameters. Our results suggest that a subjective holistic assessment of running patterns provides insight into the biomechanics of running gaits of individuals.
Accelerometer-based systems are often used to quantify human movement. This study's aim was to assess the reliability and validity of the Myotest® accelerometer-based system for measuring running stride kinematics. Twenty habitual runners ran two 60 m trials at 12, 15, 18 and 21 km·h(-1). Contact time, aerial time and step frequency parameters from six consecutive running steps of each trial were extracted using Myotest® data. Between-trial reproducibility of measures was determined by comparing kinematic parameters from the two runs performed at the same speed. Myotest® measures were compared against photocell-based (Optojump Next®) and high-frequency video data to establish concurrent validity. The Myotest®-derived parameters were highly reproducible between trials at all running speeds (intra-class correlation coefficient (ICC): 0.886 to 0.974). Compared to the photo-cell and high-speed video-based measures, the mean contact times from the Myotest® were 34% shorter and aerial times were 64% longer. Only step frequency was comparable between systems and demonstrated high between-system correlation (ICC ≥ 0.857). The Myotest® is a practical portable device that is reliable for measuring contact time, aerial time and step frequency during running. In terms of validity, it provides accurate step frequency measures but underestimates contact time and overestimates aerial time compared to photocell- and optical-based systems.
Different running patterns were associated with similar RE. Aerial runners appear to rely more on elastic energy utilization with a rapid eccentric-concentric coupling time, whereas terrestrial runners appear to propel the body more forward rather than upward to limit work against gravity. Excluding runners with a mixed running pattern from analyses did not affect study interpretation.
The aim was to identify the differences in lower limb kinematics used by high (DFhigh) and low (DFlow) duty factor (DF) runners, particularly their sagittal plane (hip, knee, and ankle) joint angles and pelvis and foot segment angles during stance. Fifty-nine runners were divided in two DF groups based on their mean DF measured across a range of speeds. Temporal characteristics and whole-body three-dimensional kinematics of the running step were recorded from treadmill runs at 8, 10, 12, 14, 16, and 18 km/h. Across speeds, DFhigh runners, which limit vertical displacement of the COM and promote forward propulsion, exhibited more lower limb flexion than DFlow during the ground contact time and were rearfoot strikers. On the contrary, DFlow runners used a more extended lower limb than DFhigh due to a stiffer leg and were midfoot and forefoot strikers. Therefore, two different lower limb kinematic mechanisms are involved in running and the one of an individual is reflected by the DF.
Lower energy cost of running (Cr) has been reported when wearing minimal (MS) vs traditional shoes (TS) on level terrain, but the effect of slope on this difference is unknown. The aim of this study was to compare Cr, physiological, and kinematic variables from running in MS and TS on different slope conditions. Fourteen men (23.4 ± 4.4 years; 177.5 ± 5.2 cm; 69.5 ± 5.3 kg) ran 14 5-min trials in a randomized sequence at 10 km/h on a treadmill. Subjects ran once wearing MS and once wearing TS on seven slopes, from -8% to +8%. We found that Cr increased with slope gradient (P < 0.01) and was on average 1.3% lower in MS than TS (P < 0.01). However, slope did not influence the Cr difference between MS and TS. In MS, contact times were lower (P < 0.01), flight times (P = 0.01) and step frequencies (P = 0.02) were greater at most slope gradients, and plantar-foot angles - and often ankle plantar-flexion (P = 0.01) - were greater (P < 0.01). The 1.3% difference between footwear identified here most likely stemmed from the difference in shoe mass considering that the Cr difference was independent of slope gradient and that the between-footwear kinematic alterations with slope provided limited explanations.
The effects of footwear and inclination on running biomechanics over short intervals are well documented. Although recognized that exercise duration can impact running biomechanics, it remains unclear how biomechanics change over time when running in minimalist shoes and on slopes. Our aims were to describe these biomechanical changes during a 50-minute run and compare them to those observed in standard shoes. Thirteen trained recreational male runners ran 50 minutes at 65% of their maximal aerobic velocity on a treadmill, once in minimalist shoes and once in standard shoes, 1 week apart in a random order. The 50-minute trial was divided into 5-minute segments of running at 0%, +5%, and -5% of treadmill incline sequentially. Data were collected using photocells, high-speed video cameras, and plantar-pressure insoles. At 0% incline, runners exhibited reduced leg stiffness and plantar flexion angles at foot strike and lower plantar pressure at the forefoot and toes in minimalist shoes from minute 34 of the protocol onward. However, only reduced plantar pressure at the toes was observed in standard shoes. Overall, similar biomechanical changes with increased exercise time were observed on the uphill and downhill inclines. The results might be due to the unfamiliarity of subjects to running in minimalist shoes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.