Background Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analysis of running mechanics in any environment. Objective measurement of running gait is an important (clinical) tool for injury assessment and provides measures that can be used to enhance performance. Objectives We aimed to systematically review the available literature investigating how wearable technology is being used for running gait analysis in adults. Methods A systematic search of the literature was conducted in the following scientific databases: PubMed, Scopus, Web of Science and SPORTDiscus. Information was extracted from each included article regarding the type of study, participants, protocol, wearable device(s), main outcomes/measures, analysis and key findings. Results A total of 131 articles were reviewed: 56 investigated the validity of wearable technology, 22 examined the reliability and 77 focused on applied use. Most studies used inertial measurement units (n = 62) [i.e. a combination of accelerometers, gyroscopes and magnetometers in a single unit] or solely accelerometers (n = 40), with one using gyroscopes alone and 31 using pressure sensors. On average, studies used one wearable device to examine running gait. Wearable locations were distributed among the shank, shoe and waist. The mean number of participants was 26 (± 27), with an average age of 28.3 (± 7.0) years. Most studies took place indoors (n = 93), using a treadmill (n = 62), with the main aims seeking to identify running gait outcomes or investigate the effects of injury, fatigue, intrinsic factors (e.g. age, sex, morphology) or footwear on running gait outcomes. Generally, wearables were found to be valid and reliable tools for assessing running gait compared to reference standards. Conclusions This comprehensive review highlighted that most studies that have examined running gait using wearable sensors have done so with young adult recreational runners, using one inertial measurement unit sensor, with participants running on a treadmill and reporting outcomes of ground contact time, stride length, stride frequency and tibial acceleration. Future studies are required to obtain consensus regarding terminology, protocols for testing validity and the reliability of devices and suitability of gait outcomes. Clinical Trial Registration CRD42021235527.
While the etiology of non-familial Parkinson's disease (PD) remains unclear, there is evidence that increased levels of tissue iron may be a contributing factor. Moreover, exposure to some environmental toxicants is considered an additional risk factor. Therefore, brain-targeted iron chelators are of interest as antidotes for poisoning with dopaminergic toxicants, and as potential treatment of PD. We, therefore, designed a series of small molecules with high affinity for ferric iron and containing structural elements to allow their transport to the brain via the neutral amino acid transporter, LAT1 (SLC7A5). Five candidate molecules were synthesized and initially characterized for protection from ferroptosis in human neurons. The promising hydroxypyridinone SK4 was characterized further. Selective iron chelation within the physiological range of pH values and uptake by LAT1 were confirmed. Concentrations of 10-20 µM blocked neurite loss and cell demise triggered by the parkinsonian neurotoxicants, methyl-phenyl-pyridinium (MPP +) and 6-hydroxydopamine (6-OHDA) in human dopaminergic neuronal cultures (LUHMES cells). Rescue was also observed when chelators were given after the toxicant. SK4 derivatives that either lacked LAT1 affinity or had reduced iron chelation potency showed altered activity in our assay panel, as expected. Thus, an iron chelator was developed that revealed neuroprotective properties, as assessed in several models. The data strongly support the role of iron in dopaminergic neurotoxicity and suggests further exploration of the proposed design strategy for improving brain iron chelation.
Inter-limb asymmetry refers to an imbalance in performance between the left and right limbs. Discrepancies throughout asymmetry research does not allow practitioners to confidently understand the effect of inter-limb asymmetries on athletic performance. Therefore, this review summarized the current literature using a meta-analytic approach, conforming to the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines to identify the association between inter-limb asymmetry and athletic performance. A literature search using PubMed, Web of Science and SPORTDiscus databases yielded 11-studies assessing the effect of inter-limb asymmetries, measured via unilateral jump performance, on bilateral jump, change of direction (COD) and sprint performance in adult sports players. The quality of evidence was assessed via a modified Downs and Black checklist and in compliance with the Grading of Recommendations Assessment Development and Evaluation. Correlation coefficients were transformed via Fishers z (Zr), meta-analysed and then re-converted to correlation coefficients. Egger’s regression presented no significant risk of bias. Vertical jump performance was not significantly affected by asymmetry (Zr = 0.053, r = 0.05; P = 0.874), whereas COD and sprint both presented significant weak associations (COD, Zr = 0.243, r = 0.24; Sprint, Zr = 0.203, r = 0.2; P < 0.01). The results demonstrate that inter-limb asymmetries seem to present a negative impact to COD and sprint performance but not vertical jump performance. Practitioners should consider implementing monitoring strategies to identify, monitor and possibly address inter-limb asymmetries, specifically for performance tests underpinned by unilateral movements such as COD and sprint performance.
The objective of this systematic review is to investigate the effects of different methods of resistance training (RT) on functional capacity in older adults. A systematic literature search was conducted using PubMed, SPORTDiscus, Web of Science, CINAHL, Cochrane CENTRAL, ClinicalTrials.gov databases, from inception to December 2021. Eligibility criteria consisted of randomised control trials (RCT’s) involving maximal-intent resistance training (MIRT), where participants (aged 60+) had specific instruction to move ‘as fast as possible’ during the concentric phase of the exercise. Twelve studies were included within the meta-analysis. Divided into functional capacity and strength-related outcomes; Improvements were evident for timed-up-and-go (p = 0.001, SMD: − 1.74 [95% CI − 2.79, − 0.69]) and knee extension one-repetition maximum (1RM) (p = 0.01, SMD: − 1.21, [95% CI − 2.17, − 0.25]), both in favour of MIRT, as well as in 30 s sit-to-stand in favour of T-STR (p = 0.04, SMD: 3.10 [95% CI 0.07, 6.14]). No statistical significance was found for combined functional capacity outcomes (p = 0.17, SMD: − 0.84, [95% CI − 2.04, 0.37]), with near-significance observed in strength-related outcomes (p = 0.06. SMD: − 0.57, [95% CI − 1.16, 0.02]) favouring MIRT. Heterogeneity for FC-outcomes was observed as Tau2 = 4.83; Chi = 276.19, df = 14, I2 = 95%, and for strength-outcomes Tau2 = 1.290; Chi = 109.65, df = 115, I2 = 86%. Additionally, MIRT elicited substantial clinically meaningful improvements (CMI) in Short Physical Performance Battery (SPPB) scores but fell short of CMI in 400 m walk test by 0.6 s. In conclusion, this systematic review highlights the lack of sufficient and quality evidence for maximal- versus submaximal-intent resistance training on functional capacity and strength in community-dwelling older adults. Study limitations revolved around lack of research, low quality (“low” PEDro score), and largely due to the fact many comparison studies did not match their loads lifted (1500 kg vs. 500 kg), making comparisons not possible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.