2017
DOI: 10.1109/tii.2017.2723602
|View full text |Cite
|
Sign up to set email alerts
|

A Simple Harmonic Reduction Method in Multipulse Rectifier Using Passive Devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
32
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(35 citation statements)
references
References 21 publications
1
32
0
2
Order By: Relevance
“…Multipulse rectifier (MPR) is one of the most common rectifiers in high power rectification system due to its simple configuration and high reliability, such as high-voltage dc transmission, aircraft converter system, telecommunication power supplies, electrochemical processes, ship propulsion system and plasma power supplies [1][2][3]. In order to improve the power quality in MPR and comply with the power quality standards, a lot of research have been done on total harmonic distortion (THD), power factor (PF), voltage distortion and so on [4][5][6][7][8][9][10][11][12][13][14][15][16]. Increasing the step number of input line current to draw sinusoidal input current is the common and effective way to reduce the THD.…”
Section: Introductionmentioning
confidence: 99%
“…Multipulse rectifier (MPR) is one of the most common rectifiers in high power rectification system due to its simple configuration and high reliability, such as high-voltage dc transmission, aircraft converter system, telecommunication power supplies, electrochemical processes, ship propulsion system and plasma power supplies [1][2][3]. In order to improve the power quality in MPR and comply with the power quality standards, a lot of research have been done on total harmonic distortion (THD), power factor (PF), voltage distortion and so on [4][5][6][7][8][9][10][11][12][13][14][15][16]. Increasing the step number of input line current to draw sinusoidal input current is the common and effective way to reduce the THD.…”
Section: Introductionmentioning
confidence: 99%
“…In Kalpana et al, 12 a DC side current injection has been utilized to reduce the harmonics. In Meng et al and Yang et al, 14,15 12-pulse rectifiers using passive auxiliary circuit at dc link are proposed. A Vienna rectifier has been reported in Izadinia and Karshenas, 13 which can enhance the power quality of the multi-pulse rectifier.…”
Section: Introductionmentioning
confidence: 99%
“…The proposed system of this paper has a simple design and control-free structure, reducing the complexity of the system. In Meng et al and Yang et al, 14,15 12-pulse rectifiers using passive auxiliary circuit at dc link are proposed. In these methods, the interphase reactor (IPR) has been replaced using a multi-tapped IPR.…”
Section: Introductionmentioning
confidence: 99%
“…Trabalhos mais recentes utilizando transformadores especiais como reatores de interfase como forma de se absorver as diferenças instantes entre as tensões de cada módulo retiĄcador e bloqueadores de sequência zero são vistos em [12], [13], os quais mostram estudos que operam com e sem circuitos auxiliares e conseguem reduzir substancialmente a distorção harmônica das correntes de entrada da estrutura.…”
Section: Reąącadores De Múltiplos Pulsosunclassified
“…A imposição triangular aumenta a corrente média do autotransformador [4], [10], mantendo o mesmo nível de potência exigido pela carga. Essa imposição, embora benéĄca para a qualidade das correntes de entrada reduzindo signiĄcatimente o THD em estruturas de múltiplos pulsos [12], e do fator de potência, gera um aumento na potência processada do núcleo magnético do autotransformador, que inicialmente era de 18,34% a 20,5%, gerando uma diminuição na potência de saída na qual o autotransformador foi originalmente projetado.…”
Section: Composição Das Correntes De Entrada Do Autotransformadorunclassified