2020
DOI: 10.1007/s10895-020-02631-x
|View full text |Cite
|
Sign up to set email alerts
|

A Sensitive Fluorescent Assay for Tetracycline Detection Based on Triple-helix Aptamer Probe and Cyclodextrin Supramolecular Inclusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 36 publications
0
7
0
Order By: Relevance
“…MIPs-AA/CQDs molecularly imprinted fluorescence sensor with carbon quantum dots and acrylic acid 1.0-60 0.17 [56] (TAP)/ γ-cyclodextrin triple-helix aptamer probe/cyclodextrin 0.005-0.1 0.0016 [57] Silver nanoparticle-encapsulated halloysite nanolumen 0.05-10 0.0124 [8] Silicon quantum dots 0.0113-1.086 0.0009 [4] Aptamer-labelled fluorescent nanoprobeintegrated shell isolated nanoparticle-enhanced fluorescence spectroscopy 0.2-400 0.0162 [22] 3-Mercaptopropionic acid-ZnS quantum dots 0.025-6 0.00003 This work…”
Section: Lod (µM) Referencesmentioning
confidence: 99%
“…MIPs-AA/CQDs molecularly imprinted fluorescence sensor with carbon quantum dots and acrylic acid 1.0-60 0.17 [56] (TAP)/ γ-cyclodextrin triple-helix aptamer probe/cyclodextrin 0.005-0.1 0.0016 [57] Silver nanoparticle-encapsulated halloysite nanolumen 0.05-10 0.0124 [8] Silicon quantum dots 0.0113-1.086 0.0009 [4] Aptamer-labelled fluorescent nanoprobeintegrated shell isolated nanoparticle-enhanced fluorescence spectroscopy 0.2-400 0.0162 [22] 3-Mercaptopropionic acid-ZnS quantum dots 0.025-6 0.00003 This work…”
Section: Lod (µM) Referencesmentioning
confidence: 99%
“…Upon target-aptamer binding, the THMS is disassembled and releases the STP, which results in fluorescence quenching due to F-Q proximity. Whereas this example represents a turn-off fluorescence approach, the same principle can be used to design a turn-on assay when F and Q in the STP are replaced by two pyrenes, which are strongly fluorescent only when the dimer is formed at close proximity . Another turn-on approach can be designed using dual THMS .…”
Section: Fluorescent Aptasensors Without Signal Amplificationmentioning
confidence: 99%
“…Structure-switching fluorescent aptasensors have also been in the focus of TET assay developments. He et al designed a turn-on fluorometric assay for TET based on THMS formed by label-free aptamer and bis-pyrene-labeled STP . TET-aptamer binding caused the formation of pyrene excimers, whose fluorescence could be further enhanced by γ-cyclodextrin to quantify TET within a linear concentration range of 5 to 100 nM and with an LOD of 1.6 nM (∼0.7 ng mL –1 ).…”
Section: Application Of Fluorescent Aptasensor For the Detection Of F...mentioning
confidence: 99%
See 2 more Smart Citations