2013
DOI: 10.1039/c3ay40757h
|View full text |Cite
|
Sign up to set email alerts
|

A rapid reversed-phase HPLC method for the simultaneous analysis of olanzapine and simvastatin in dual nanostructured lipid carriers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…A SIMA solution of ca. 1 mg mL −1 is obtained and confirmed by the absence of the SIM peak in HPLC analysis [17] . Two working standard solutions containing the five analytes were prepared at the concentrations of 100 and 10 µg mL −1 by dilution of each stock solution with the mobile phase (acetonitrile:buffer, 50:50).…”
Section: Methodsmentioning
confidence: 63%
“…A SIMA solution of ca. 1 mg mL −1 is obtained and confirmed by the absence of the SIM peak in HPLC analysis [17] . Two working standard solutions containing the five analytes were prepared at the concentrations of 100 and 10 µg mL −1 by dilution of each stock solution with the mobile phase (acetonitrile:buffer, 50:50).…”
Section: Methodsmentioning
confidence: 63%
“…The quantification of the two drugs, OL and SV, was performed using a HPLC method previously validated . A Shimadzu LC-2010HT apparatus equipped with a quaternary pump (LC-20AD), an autosampler unit (SIL-20AHT), a CTO-10AS oven, and a SPD-M2OA detector was employed.…”
Section: Methodsmentioning
confidence: 99%
“…The quantification of the two drugs, OL and SV, was performed using a HPLC method previously validated. 53 A Shimadzu LC-2010HT apparatus equipped with a quaternary pump (LC-20AD), an autosampler unit (SIL-20AHT), a CTO-10AS oven, and a SPD-M2OA detector was employed. The column used for the analysis was a Luna Phenyl-Hexyl, Phenomenex (Torrance, CA, USA), with 5 μm particle size, 3 mm internal diameter, and 150 mm length.…”
Section: Molecular Pharmaceuticsmentioning
confidence: 99%
“…Column efficiency was also evidenced for all drugs, since the number of theoretical plates (T. Plates), tailing factor (T. Factor), and resolution were compliant with ICH criteria. Even though the capacity factor (k ) for acyclovir and clobetasol was slightly beneath 2.0, according to the British Pharmacopoeia, this value can still be accepted (k < 1.5) [31].…”
Section: System Suitabilitymentioning
confidence: 99%