“…However, studies on manikins always have to be interpreted with great caution when considering the clinical implications of airway management in anaesthesiology . The anatomical correlation between the level of the teeth and the hypopharynx often varies from manikins to patients and could enable easier application in manikins . Furthermore, the tissue conditions are less realistic due to the absence of mucus and other fluids like blood that could impede the view.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, studies on manikins always have to be interpreted with great caution when considering the clinical implications of airway management in anaesthesiology . The anatomical correlation between the level of the teeth and the hypopharynx often varies from manikins to patients and could enable easier application in manikins . Furthermore, the tissue conditions are less realistic due to the absence of mucus and other fluids like blood that could impede the view.…”
Section: Discussionmentioning
confidence: 99%
“…The airway of the ALS Simulator advanced manikin (Laerdal Medical AS, Stavanger, Norway) offers sufficiently realistic conditions concerning the insertion of supraglottic airway devices and the application of a tracheal tube …”
Section: Methodsmentioning
confidence: 99%
“…The adult high-fidelity simulator SimMan (Laerdal medical AS, Stavanger, Norway) offers sufficient conditions concerning the airway anatomy 14. The airway of the simulator was modified by the producer’s default settings, as follows: pharyngeal obstruction, tongue swelling, reduced range of head reclining and jaw trismus.…”
Section: Methodsmentioning
confidence: 99%
“…In einer CT-basierten anatomischen Studie konnte aus 13 Atemwegstrainern lediglich einer identifiziert werden, der annähernd die menschliche Anatomie abbildete (Laerdal Airway Management Trainer, Laerdal Medical GmbH, Puchheim) [6]. Ein wesentliches Problem aller Phantome ist die unzureichende Nachbildung der Speiseröhre.…”
Section: Training An Manikinsunclassified