2015
DOI: 10.1016/j.bios.2015.06.080
|View full text |Cite
|
Sign up to set email alerts
|

A polydopamine-modified optical fiber SPR biosensor using electroless-plated gold films for immunoassays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
52
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 137 publications
(52 citation statements)
references
References 42 publications
(44 reference statements)
0
52
0
Order By: Relevance
“…Toma and Tawa [140], in 2016, chose polydopamine (PDA) as the coupling agent for a surface plasmon-enhanced fluorescence spectroscopy (SPFS)-based sensor for IL-6 detection ( Figure 6A). It has already been used as bifunctional linker in many biosensing platforms developed for diverse application and was found to enhance the SPFS signal [145][146][147][148]. The thickness of the PDA layer on glass substrate coated with gold was optimized to 1.5 nm to achieve the best SPFS response.…”
Section: Coupling Agentmentioning
confidence: 99%
“…Toma and Tawa [140], in 2016, chose polydopamine (PDA) as the coupling agent for a surface plasmon-enhanced fluorescence spectroscopy (SPFS)-based sensor for IL-6 detection ( Figure 6A). It has already been used as bifunctional linker in many biosensing platforms developed for diverse application and was found to enhance the SPFS signal [145][146][147][148]. The thickness of the PDA layer on glass substrate coated with gold was optimized to 1.5 nm to achieve the best SPFS response.…”
Section: Coupling Agentmentioning
confidence: 99%
“…Detailed fabrication process of the fiber optic SPR sensor and experimental setup can be found in the Methods. In the process of biological modification and detection, the optic fiber SPR biosensor is firstly modified with a biological crosslinked membrane (polydopamine (PDA)) by the surface functionalization method as reported in the previous literature 17 . Afterward, we immobilize the anti-CRP monoclonal antibody on the sensor surface for the CPR specific detection.…”
Section: Introductionmentioning
confidence: 99%
“…In order to evaluate the sensitivity of the SPR sensors to the bulk refractive index, refractometric experiments were performed in this study, according to previous reports (Shi et al, 2015;Slav´k et al, 2002). A set of ethanol solutions prepared in deionized water with different refractive indexes were used.…”
Section: Sensitivity Of Mip/gnps/rgo-coated Spr Sensor Chipmentioning