2017
DOI: 10.1016/j.bios.2016.09.041
|View full text |Cite
|
Sign up to set email alerts
|

A point-of-use microfluidic device with integrated photodetector array for immunoassay multiplexing: Detection of a panel of mycotoxins in multiple samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(14 citation statements)
references
References 19 publications
0
14
0
Order By: Relevance
“…To decrease the complexity of the assay which used multiwavelength or light scattering for quantification, in 2017, Soares et al developed a novel integrated device with manually operated magnetic valves for the detection of ochratoxin A (OTA), aflatoxin B1 (AFB1), and deoxynivalenol (DON). e LOD of these three kinds of fungi was 100 ng/mL, 100 ng/mL, and 3 ng/mL, respectively [63]. In some conventional optimized magneto-immunoassays [77,78], fluorescent [79] and magnetic beads (MB) incubation are conveyed under agitation and MB washings rely on magnets, which hinder the integration with a low-cost POC device.…”
Section: Magnetic Nondigital Microfluidic System Inmentioning
confidence: 99%
“…To decrease the complexity of the assay which used multiwavelength or light scattering for quantification, in 2017, Soares et al developed a novel integrated device with manually operated magnetic valves for the detection of ochratoxin A (OTA), aflatoxin B1 (AFB1), and deoxynivalenol (DON). e LOD of these three kinds of fungi was 100 ng/mL, 100 ng/mL, and 3 ng/mL, respectively [63]. In some conventional optimized magneto-immunoassays [77,78], fluorescent [79] and magnetic beads (MB) incubation are conveyed under agitation and MB washings rely on magnets, which hinder the integration with a low-cost POC device.…”
Section: Magnetic Nondigital Microfluidic System Inmentioning
confidence: 99%
“…Simultaneous detection of multiple mycotoxins by a microfluidic a-Si:H photosensors was also realized. Soares et al [ 117 ] developed a microfluidic multiplexed immunochip utilizing a permanent magnet valve and a single negative pressure source for the simultaneous detection of OTA, AFB1, and DON (three mycotoxins) by the integrated a-Si:H photodetector. Three mycotoxins of 100 μg/L for OTA and DON, and 3 μg/L for AFB1 were detected in less than 20 min.…”
Section: Application Of Microchips For the Determination Of Mycotomentioning
confidence: 99%
“…The content of substances is proportional to the intensity of the luminous signal. It can realize sensitive detecting of trace markers in samples and be used as a conventional detector in microfluidic chips ( Hu et al, 2017 ; Soares et al, 2017 ; Xie et al, 2019 ). A biochip with 3 × 8 wells array was constructed to simultaneously detect three cardiac markers cTnI, CK-MB, and Myo ( Zhao et al, 2019 ).…”
Section: Introductionmentioning
confidence: 99%