2016
DOI: 10.1016/j.aca.2016.06.005
|View full text |Cite
|
Sign up to set email alerts
|

A novel reagentless glutamate microband biosensor for real-time cell toxicity monitoring

Abstract: Disclaimer UWE has obtained warranties from all depositors as to their title in the material deposited and as to their right to deposit such material. UWE makes no representation or warranties of commercial utility, title, or fitness for a particular purpose or any other warranty, express or implied in respect of any material deposited. UWE makes no representation that the use of the materials will not infringe any patent, copyright, trademark or other property or proprietary rights. UWE accepts no liability f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 28 publications
0
6
0
1
Order By: Relevance
“…Also, in this case electrochemical enzymatic sensors based on glutamate oxidase or glutamate dehydrogenase are excellent candidates for this purpose. 71 , 72 …”
Section: Future Oportunities For the Integration Of Biosensors In Bbb-ocmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, in this case electrochemical enzymatic sensors based on glutamate oxidase or glutamate dehydrogenase are excellent candidates for this purpose. 71 , 72 …”
Section: Future Oportunities For the Integration Of Biosensors In Bbb-ocmentioning
confidence: 99%
“…For LDH detection, an electrochemical enzymatic sensor functionalized with lactate oxidase and a redox mediator can be used, such as that reported by Park et al Another real-time biomarker for cell cytotoxicity analysis is glutamate that can be affected by neuronal toxicity. Also, in this case electrochemical enzymatic sensors based on glutamate oxidase or glutamate dehydrogenase are excellent candidates for this purpose. , …”
Section: Future Oportunities For the Integration Of Biosensors In Bbb-ocmentioning
confidence: 99%
“…Another advantage of microband biosensors is that they exhibit steady‐state behaviour in the absence of stirring. Consequently, changes in the concentration of the target biomarker, which occur during cytotoxic challenge to the cells, can be readily measured .…”
Section: Figurementioning
confidence: 99%
“…Their work was based on the enzymatic reactions of glutamate oxidase [20][21], glutamate dehydrogenase [22][23], and glutamate synthetase and glutamate decarboxylase [24][25][26]. The enzymes were immobilized on NiÀ Pd nanoparticles [27], fiber optic detector [28], solid electrode based on unplasticized chitosan [29], gold electrode modified with polyaniline and nanoparticles of polypropylor [30], and thick-film platinum electrode [31].…”
Section: Introductionmentioning
confidence: 99%