1968
DOI: 10.1530/jrf.0.0160515
|View full text |Cite
|
Sign up to set email alerts
|

A New Technique for Introducing Iuds Into Rat Uteri

Abstract: Summary. Intra-uterine contraceptive devices (IUDs) were made from monofilament nylon and inserted by a non-surgical technique through the cervical os of rats so as to be wholly within the uterine lumen. Most of these devices were retained and exhibited local contraceptive action in the uterine horn in which they were placed. This new method of insertion in rats offers advantages over other ways of studying the physiological and biochemical factors important to IUD function.Increasing acceptance of the intra-u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

1969
1969
1994
1994

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 10 publications
(5 reference statements)
0
5
0
Order By: Relevance
“…The vaginal route has been used to insert an IUD (Wrenn, Wood & Bitman, 1968), for egg transfer (Bennett & Vickery, 1970), or to apply drugs to the endometrium (Barker, 1967) but, as far as I know, none of the numerous studies on the DCR in the rat has used this approach. The transcervical route used in the present study avoids the trauma and expenditure of time associated with laparotomy.…”
mentioning
confidence: 99%
“…The vaginal route has been used to insert an IUD (Wrenn, Wood & Bitman, 1968), for egg transfer (Bennett & Vickery, 1970), or to apply drugs to the endometrium (Barker, 1967) but, as far as I know, none of the numerous studies on the DCR in the rat has used this approach. The transcervical route used in the present study avoids the trauma and expenditure of time associated with laparotomy.…”
mentioning
confidence: 99%
“…The incidence of uterine exúdate in this experiment was low, only 4-3% of the IUD horns showing visible amounts. In a previous study (Wrenn et al, 1968), 54% of the IUD horns contained exúdate in 10to 21-day pregnant rats. This suggests that the rat may be more susceptible to infection and/or inflammatory reaction during later pregnancy than at earlier times, and seems to merit further investigation.…”
Section: Discussionmentioning
confidence: 78%
“…The recent development in our laboratory of a method for the cervical introduction of an IUD lying wholly within the lumen of one uterine horn of the albino rat has provided an experimental preparation that facilitates studies of chemical differences between the infertile IUD horn and the contralateral horn possessing normal fertility (Wrenn, Wood & Bitman, 1968). This method avoids the trauma of surgery and the associated inflammatory alterations involved in placing a suture through the walls of the uterus.…”
Section: Introductionmentioning
confidence: 99%
“…In mice, however, there is a decrease in the number of implantations in the contralateral horn (Marston & Kelly, 1969), and in rats the IUD-containing uterus can support implantations . Previous investigators have not described the formation of exúdate in hamsters as a response to an IUD, but in rats a visible accumulation of fluid was noted in 54% of the IUD-containing uteri (Wrenn, Wood & Bitman, 1968). El Sahwi & Moyer (1971) noted that the antifertility action of a silicone-plastic IUD was in proportion to the number of leucocytes observed in the uterine lumen.…”
Section: Resultsmentioning
confidence: 97%