1989
DOI: 10.1080/00223638.1989.11737029
|View full text |Cite
|
Sign up to set email alerts
|

A New Spectrophotometer for Measuring the Spectral Reflectance of Gastric Mucous Membrane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

1995
1995
2021
2021

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(21 citation statements)
references
References 1 publication
0
21
0
Order By: Relevance
“…The technology of the FICE system was invented by Miyake et al [17][18][19][20] and developed with the aim of enhancing the capillary pattern and the pit patterns in endoscopic images. The Japanese society of spectral imaging for endoscopy recommended naming this system 'flexible spectral imaging color enhancement' in June 2008.…”
Section: Instrumentmentioning
confidence: 99%
“…The technology of the FICE system was invented by Miyake et al [17][18][19][20] and developed with the aim of enhancing the capillary pattern and the pit patterns in endoscopic images. The Japanese society of spectral imaging for endoscopy recommended naming this system 'flexible spectral imaging color enhancement' in June 2008.…”
Section: Instrumentmentioning
confidence: 99%
“…The NICE classification with or without magnification is considered valid in the USA, Europe, and Japan for differentiating neoplastic and non-neoplastic polyps [33]. Regarding of IEE-ME techniques, there have been many studies on both NBI-ME and FICE-ME [12,13,17,23,[34][35][36]. These studies have reported accuracy of 93.…”
Section: Clinical Advantages Of Nbi and Ficementioning
confidence: 99%
“…FICE was formerly known as Fuji Intelligent Color Endoscopy, but this definition has recently changed. FICE depends on optical filters and spectral-estimation technology to reconstruct images at different wavelengths based on WL images [17,18]. The suitable RGB wavelength settings and contrast levels for FICE to evaluate colorectal polyps are 540 (1) nm, 460 (4) nm, and 460 (4) nm, respectively [19,20].…”
Section: Image-enhanced Endoscopymentioning
confidence: 99%
“…FICE is an imaging enhancement system based on the technique of "spectrum estimation," which was developed by the Research Center for Frontier Medical Engineering, Chiba University. 6 Use of this approach is becoming increasingly common. FICE involves irradiation of a subject with white light and taking of images using a charge-coupled device ͑CCD͒ camera in a regular endoscopic system.…”
Section: Introductionmentioning
confidence: 99%