8th International Conference on Power Electronics - ECCE Asia 2011
DOI: 10.1109/icpe.2011.5944715
|View full text |Cite
|
Sign up to set email alerts
|

A new phase-shifted full-bridge converter with maximum duty operation for server power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 11 publications
0
16
0
Order By: Relevance
“…B) Extra transistor Q 3 The ZVS condition of the extra transistor Q 3 is determined by the energy of leakage inductance. It can be expressed as,…”
Section: Soft-switching Conditionmentioning
confidence: 99%
See 1 more Smart Citation
“…B) Extra transistor Q 3 The ZVS condition of the extra transistor Q 3 is determined by the energy of leakage inductance. It can be expressed as,…”
Section: Soft-switching Conditionmentioning
confidence: 99%
“…Over the last two decades, the most researches focus on the improved ZVS and ZVZCS phase-shifted full-bridge circuit [1][2][3][4][5][6] and their applications. But comparatively, the research on soft switching push-pull converter is very seldom.…”
Section: Introductionmentioning
confidence: 99%
“…Given the resonance between transformer leakage inductance and parasitic junction capacitance of a rectifier diode, serious voltage spikes across the diode rectifier are generated [3], which increases the diode voltage rating and causes electromagnetic interference problems. Excessive circulating current in the primary side during the freewheeling interval also increases the primary side conduction and turn-off switching losses of the lagging-leg switches [4]- [6]. From the corresponding waveforms of a traditional PSFB converter shown in Fig.…”
Section: Introductionmentioning
confidence: 99%
“…In order to extend the ZVS range and eliminate voltage spike of diode rectifier, additional auxiliary circuits are required [2], [4]- [6], [8]- [11], [14], which increase complexity of the converter and cause additional conduction losses.…”
Section: Introductionmentioning
confidence: 99%
“…A number of research papers have been published in literature to improve the range of ZVS operation for converter [3][4][5][6]. The range of ZVS can be extended by increasing stored energy of inductance using high leakage inductance of transformer or adding series inductance.…”
Section: Introductionmentioning
confidence: 99%