IEEE Power Engineering Society General Meeting, 2004.
DOI: 10.1109/pes.2004.1372973
|View full text |Cite
|
Sign up to set email alerts
|

A new hybrid current sensor for high-voltage applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 15 publications
0
8
0
Order By: Relevance
“…Performance of any digital filter can be reliably evaluated only in case of input impacts approximating, by their kind, actual secondary current waveforms of primary instrument current converters (mostly represented by current transformers or other converters [3], [14]- [18]) the protection using the evaluated filter is connected to. For these purposes, a power system and MP-based (digital) protection current measuring element structural model was developed and reproduced in MicroCAP dynamic modeling environment.…”
Section:   mentioning
confidence: 99%
“…Performance of any digital filter can be reliably evaluated only in case of input impacts approximating, by their kind, actual secondary current waveforms of primary instrument current converters (mostly represented by current transformers or other converters [3], [14]- [18]) the protection using the evaluated filter is connected to. For these purposes, a power system and MP-based (digital) protection current measuring element structural model was developed and reproduced in MicroCAP dynamic modeling environment.…”
Section:   mentioning
confidence: 99%
“…However, the buffer layer deteriorates the frequency response [66] and the stability [67]. The mono-shielding electrode was optimized as a grid type, shown in Figure 10 [68].…”
Section: The Integrated Optical E-field Sensormentioning
confidence: 99%
“…A buffer layer (Si or SiO 2 ) should be added between the waveguide and electrode to eliminate the influence of the metal on the waveguide. However, the buffer layer deteriorates the frequency response [ 66 ] and the stability [ 67 ]. The mono-shielding electrode was optimized as a grid type, shown in Figure 10 [ 68 ].…”
Section: The Integrated Optical E-field Sensormentioning
confidence: 99%
“…In recent years, the research on HOCT has been focused on simplifying the structure in the HV environment with reduced power consumption. In [15], a passive integrated-optic Pockels cell (IOPC) was used to modulate the light corresponding to the signals from the Rogowski coil. However, since IOPC is susceptible to the polarization state of the light, a polarizing (PZ) fiber and a polarization maintaining (PM) fiber are needed for the input and output of the sensor head, respectively, which are potentially vulnerable to external pressure and vibration.…”
Section: Introductionmentioning
confidence: 99%