2018
DOI: 10.1016/j.electacta.2018.01.204
|View full text |Cite
|
Sign up to set email alerts
|

A new electrochemical sensor with the Refreshable Silver Liquid Amalgam Film multi-Electrode for sensitive voltammetric determination of vitamin K2 (menaquinone)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 34 publications
0
10
0
Order By: Relevance
“…The surface of the electrode can be equal to 0.4, 0.8 and 1.2 mm 2 , depending on the number of the protruding silver discs. 71 Great advantage of the MF-AgSAE, AgLAF-AgSAE and the RAgLAFm-E is the possibility to strictly control time, when the electrode is inside the analyzed solution.…”
Section: Mercury and Amalgams Based Electrodesmentioning
confidence: 99%
“…The surface of the electrode can be equal to 0.4, 0.8 and 1.2 mm 2 , depending on the number of the protruding silver discs. 71 Great advantage of the MF-AgSAE, AgLAF-AgSAE and the RAgLAFm-E is the possibility to strictly control time, when the electrode is inside the analyzed solution.…”
Section: Mercury and Amalgams Based Electrodesmentioning
confidence: 99%
“…However, due to the introduction of a biological matrix, the peak height was lower than in the plain supporting electrolyte, which translates into lesser sensitivity. As described in [Jedlińska, Strus, and Baś 2018], signi cant improvement in repeatability and reproducibility was obtained when the cathodic scan preceded the anodic one.…”
Section: Optimization Of Experimental Conditionsmentioning
confidence: 78%
“…For the first time, the Refreshable Silver Liquid Amalgam Film multi-electrode (RAgLAFm-E) was used to quantify Vit K 2 (menaquinone). The electrochemical behavior of Vit K 2 was investigated using cyclic voltammetry (CV), and it was effectively utilized to detect Vit K 2 in pharmaceuticals and food samples (Jedlin ´ska et al 2018). In recent years, many electrochemical sensors for detecting Vit K have been developed, but fiber optic sensors have not received much attention (Tabassum and Gupta 2016).…”
Section: Detection Of Vit Kmentioning
confidence: 99%
“…The electrochemical sensing of vitamins is widely used by various researchers across the globe (Huang et al 2021). It is used for finding the concentration of Vit A (Lv et al 2017), Vit D(Sarkar et al 2018, Vit K 2 (Jedlin ´ska et al 2018), and other vitamins.…”
Section: Introductionmentioning
confidence: 99%