2020
DOI: 10.1149/1945-7111/ab64d6
|View full text |Cite
|
Sign up to set email alerts
|

Review—Voltammetric Sensors with Laterally Placed Working Electrodes: A Review

Abstract: Voltammetric sensors with laterally placed working electrode are an interesting alternative to classic electrodes since they offer enhanced performance in electroanalysis. Their characteristics include easier preparation for measurement, removal of interferences and gas bubbles, amplification of mass-transport, and possibility of miniaturization and automation. In this review, construction and characteristics of the custom-designed in our team cyclically renewable, silver, gold, bismuth, glassy carbon, ceramic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 77 publications
1
12
0
Order By: Relevance
“…In voltammetric immunosensors, the current is obtained from the analyte measurements when the potential is changed. The potential between the working and reference electrodes changes over time, and the current generated between the working and counter electrodes vi the electrochemical reaction of the analytes is measured [23]. The signal originates from the oxidoreduction processes at the surface of the working electrode, caused by the electroactive species.…”
Section: Voltammetric Immunosensorsmentioning
confidence: 99%
“…In voltammetric immunosensors, the current is obtained from the analyte measurements when the potential is changed. The potential between the working and reference electrodes changes over time, and the current generated between the working and counter electrodes vi the electrochemical reaction of the analytes is measured [23]. The signal originates from the oxidoreduction processes at the surface of the working electrode, caused by the electroactive species.…”
Section: Voltammetric Immunosensorsmentioning
confidence: 99%
“…This was due to the increase in the film thickness, which resulted in the reduction of the electron transfer rate and a decrease in conductivity. 31,32 Fig. 2 FESEM images at different resolution (a-c) and the XRD pattern (d) of the as-synthesised hexagonal shaped cobalt oxide nanosheets.…”
Section: Electrochemical Activity Analysismentioning
confidence: 99%
“…Before each measurement, the electrode is cleaned and activated 227 . Electrochemical cleaning, which involves cycling the potential or holding the potential at a judiciously selected predetermined value for a defined period of time, can be used to condition the electrode surface 225,228 .…”
Section: Electrode Conditioning and Regenerationmentioning
confidence: 99%