2015
DOI: 10.1504/ijbet.2015.066962
|View full text |Cite
|
Sign up to set email alerts
|

A multiple signal classification approach for photoplethysmography signals in healthy and athletic subjects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 30 publications
0
9
0
Order By: Relevance
“…The filtered signal is used for calculation of all parameters’ values for hand movement MNAs detection. The DWT was applied to non-stationary signals to effectively get AR parameters [43-45]. In this paper, as shown in Fig.…”
Section: Materials and Preprocessingmentioning
confidence: 99%
See 1 more Smart Citation
“…The filtered signal is used for calculation of all parameters’ values for hand movement MNAs detection. The DWT was applied to non-stationary signals to effectively get AR parameters [43-45]. In this paper, as shown in Fig.…”
Section: Materials and Preprocessingmentioning
confidence: 99%
“…In this paper, as shown in Fig. 2, the high pass filter output is processed by discrete wavelet transform (DWT) for the AR model parameter calculation since AR parameter requires more detailed time-varying frequency information, the DWT is additionally applied only to get the AR parameter more effectively [43, 45]. Fig.…”
Section: Materials and Preprocessingmentioning
confidence: 99%
“…The core problem is to design efficient software or develop more advanced data processing methods for how to organize and understand biological data more effectively [ 16 ]. At present, the research work of bioinformatics mainly focuses on gene sequence analysis, biodiversity measurement, protein structure prediction, and protein and gene expression analysis [ 17 ]. Gene sequence analysis, for example, phage Φ - X174, is the first measured complete genome sequences of an organism.…”
Section: Proposed Methodsmentioning
confidence: 99%
“…PPG has been widely accepted by the International Organization for Standardization (ISO) and the European Committee for Oxygen Saturation Measurement. When a finger is placed on the PPG device, it can easily record a high-quality pulse signal 5 8 . Pulse signals from PPG were preprocessed to improve signal quality and estimate heart rate 9 11 .…”
Section: Introductionmentioning
confidence: 99%