Abstract: A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator, and was operated during Operational Period 1.1 (OP1.1) to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344x784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024x1024 pixel Allied Vision Te… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
23
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 12 publications
(24 citation statements)
references
References 5 publications
1
23
0
Order By: Relevance
“…21 The limiter was seen with high temporal resolution (∼400 Hz in the IR and ∼100 Hz in the visible) and sub-mm spatial resolution on five of its nine tiles. The filtered visible camera provided absolutely calibrated measurements of carbon and hydrogen light, and therefore inputs to particle balance calculations.…”
Section: Diagnostics For Plasma Edge and In-vessel Componentsmentioning
confidence: 93%
“…21 The limiter was seen with high temporal resolution (∼400 Hz in the IR and ∼100 Hz in the visible) and sub-mm spatial resolution on five of its nine tiles. The filtered visible camera provided absolutely calibrated measurements of carbon and hydrogen light, and therefore inputs to particle balance calculations.…”
Section: Diagnostics For Plasma Edge and In-vessel Componentsmentioning
confidence: 93%
“…The effect of a perturbing n = 1 EX/P5-5 trim coil field on the limiter temperatures was examined. In figure 1 a stereotypical limiter IR camera image is shown [6,7]. Three lines are drawn across the limiter from which temperature data is extracted.…”
Section: Measurementsmentioning
confidence: 99%
“…The effect of error fields on limiter heat loads were also explored with the trim coils. A high resolution infrared camera [6,7] gave detailed imagery of the limiters during the pulse. Low limiter temperatures limited the range of diagnostic coverage during this first campaign.…”
Section: Introductionmentioning
confidence: 99%
“…W7-AS [4,5], W7-X [6,7], LHD [8,9], HSX [10,11]) and tokamaks (e.g. DIII-D [12,13], NSTX [14,15], TEXTOR-DED [16,17]), yet their interpretation in terms of local quantities can be challenging due to line of sight integration effects.…”
Section: Introductionmentioning
confidence: 99%
“…One particular application in fusion plasmas is the characterization of particle fluxes and erosion on limiter or divertor targets inferred from observations by a camera with an appropriate filter. At W7-X, such a diagnostic system has been dedicated to the analysis of the startup limiter during the first operation phase (OP1.1) from observation of H α emission (λ = 656.2 nm) [6,7]. These measurements are based on the "S/XB formalism" [18,2] Γ = S X B · Φ (1) which relates the measured photon flux Φ to the particle flux onto the limiter Γ through an appropriate choice of conversion factor S X B .…”
Section: Introductionmentioning
confidence: 99%