2017
DOI: 10.1007/s00216-017-0756-1
|View full text |Cite
|
Sign up to set email alerts
|

A fluorescent immunochromatographic strip test using a quantum dot-antibody probe for rapid and quantitative detection of 1-aminohydantoin in edible animal tissues

Abstract: A rapid, simple, and sensitive fluorescent immunochromatographic strip test (ICST) based on quantum dots (QDs) has been developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. To achieve this, QD-labeled antibody conjugates, which consist of CdSe/ZnS QDs and monoclonal antibodies, were prepared by an activated ester method. Under optimal conditions, with the nitrophenyl derivative of AHD as the target, the ICST had a linear range from 0.1 to 100 ng/mL, with a correla… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 28 publications
0
13
0
Order By: Relevance
“…2013; Le et al . 2018) a two‐reaction system and double‐test lines (T1, T2) to improve the accuracy, including rabbit IgG with Gold–goat anti‐rabbit IgG conjugate and NDV antibody–HN with Gold‐HN conjugate for the control line (C) and double‐test lines (T1, T2), respectively (Fig. 1a,b).…”
Section: Methodsmentioning
confidence: 99%
“…2013; Le et al . 2018) a two‐reaction system and double‐test lines (T1, T2) to improve the accuracy, including rabbit IgG with Gold–goat anti‐rabbit IgG conjugate and NDV antibody–HN with Gold‐HN conjugate for the control line (C) and double‐test lines (T1, T2), respectively (Fig. 1a,b).…”
Section: Methodsmentioning
confidence: 99%
“…The recovery fell in the range of 76.3-98.4%, and the coefficient of variation was less than 15.0% (Le et al, 2016). The same group subsequently applied the QD-ICA technique to the detection of AHD (Le et al, 2018), and achieved a LOD of 0.14 μg/kg, which was below the MRPL of 1 μg/kg for AHD set by the European Commission. This method offered a fast and simple on-site detection of the desired analyte.…”
Section: Quantum Dot Immunochromatographic Assaymentioning
confidence: 97%
“…In a Cd-negative sample, the fluorescently labelled mAb (FM-mAb) binds to the coating antigen Cd-ITCBE-BSA at the T line. The remaining unbound FM-mAb migrates upward along the NC membrane and binds to the goat anti-mouse secondary antibody where it reaches the C line (Le, Zhang, Wu, Shi, & Cao, 2018). In a Cd-positive sample, FM-mAb binds to Cd, and unreacted FM-mAb and conjugate migrate along the NC membrane.…”
Section: Quantitative Detection Using the Fluorescent Immunoassay Stripmentioning