Abstract: A surface plasmon resonance sensor based on a dual-groove photonic crystal fiber (PCF) for refractive index (RI) sensing with ultra-wide measurement range and high sensitivity is designed and theoretically investigated. The upper and right grooves of the PCF as different sensing channels are coated with Au or Au-TiO 2 compound film. The influence of the parameters on the sensing performance of the designed sensor are analyzed. Numerical results show that the maximum wavelength sensitivity (WS) of 6800 nm/RIU w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(14 citation statements)
references
References 30 publications
0
14
0
Order By: Relevance
“…The energy received by the optical fiber probe can be attenuated substantially to even render it undetectable in practice. The minimum losses of the sensors and the corresponding resonance wavelengths 36–102 are calculated and shown in Fig. 10.…”
Section: Numerical Resultsmentioning
confidence: 99%
“…The energy received by the optical fiber probe can be attenuated substantially to even render it undetectable in practice. The minimum losses of the sensors and the corresponding resonance wavelengths 36–102 are calculated and shown in Fig. 10.…”
Section: Numerical Resultsmentioning
confidence: 99%
“…Gold is a commonly-used plasma material in many SPR devices due to its high resonance shift capability and chemical stability. The TiO 2 film is deposited on the gold layer to increase the electromagnetic field extension from the metal film to the analyte, enhancing the interaction of the evanescent wave with the analyte [28]. It is noteworthy that most of the planar-layer silica connects with the air holes directly, where the electromagnetic field tends to be partially reflected to the metal film because of the considerable RI difference at the silica-air interface.…”
Section: Structural and Theoretical Modelingmentioning
confidence: 99%
“…where, ∆λ peak is the shift of the peak in nm due to the variation of the RIU ∆n a . The corresponding sensor resolution is evaluated as follows [37],…”
Section: Sensor Structure Design Fabrication Feasibility Analysis and Numerical Modelingmentioning