Designing Highly Sensitive Surface Plasmon Resonance Sensor With Dual Analyte Channels

Abstract: The ease of controlling waveguide properties through unparalleled design flexibility has made the photonic crystal fiber (PCF) an attractive platform for plasmonic structures. In this work, a dual analyte channel's highly sensitive PCF bio-sensor is proposed based on surface plasmon resonance (SPR). In the proposed design, surface plasmons (SPs) are excited in the inner flat portion of two rectangular analyte channels where gold (Au) strip is deposited. Thus, the surface roughness that might be generated durin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(8 citation statements)
references
References 38 publications
0
1
0
Order By: Relevance
“…In the preceding section, the various devices used in health monitoring are described in detail. This section is devoted to presenting the methods executed in these monitoring systems [43][44][45][46][47][48][49][50][51][52][53][54][55]. Specifically, refs.…”
Section: Current Methods and Approaches In Remote Health Monitoringmentioning
confidence: 99%
See 3 more Smart Citations
“…In the preceding section, the various devices used in health monitoring are described in detail. This section is devoted to presenting the methods executed in these monitoring systems [43][44][45][46][47][48][49][50][51][52][53][54][55]. Specifically, refs.…”
Section: Current Methods and Approaches In Remote Health Monitoringmentioning
confidence: 99%
“…Specifically, refs. [43][44][45][46][47][48] present channel characteristics studies for different mentioned devices whereas [49,50] are devoted to WCE advancements. Refs.…”
Section: Current Methods and Approaches In Remote Health Monitoringmentioning
confidence: 99%
See 2 more Smart Citations
“…To check the performance of the proposed SP-SMF model, the sensitivity has been calculated which is the variation of refractive index occurs with the change of analytes and the voltage. The sensitivity (S) of the proposed model with respect to wavelength and the voltage has been measured by the following equation[33]:4 where is the variation of the refractive index, and is the change of voltage. Correspondingly, Fig.…”
mentioning
confidence: 99%