2020
DOI: 10.1016/j.epsr.2019.106055
|View full text |Cite
|
Sign up to set email alerts
|

A droop line tracking control for multi-terminal VSC-HVDC transmission system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…According to the power frequency static characteristics of the generator set, the distribution of active and reactive power can meet the reasonable requirements. By using the inverse fine-tuning parameters, the inverter output voltage amplitude is reasonable and the frequency is stable, to realize the stable operation of DG parallel system of microgrid [10]. e frequency droop characteristic curve similar to the traditional generator is selected as the control mode of microsource, that is, the stable frequency and voltage are obtained by P-F droop control and q-u droop control, respectively.…”
Section: Principle Analysis Of the Traditional Droop Control Methodsmentioning
confidence: 99%
“…According to the power frequency static characteristics of the generator set, the distribution of active and reactive power can meet the reasonable requirements. By using the inverse fine-tuning parameters, the inverter output voltage amplitude is reasonable and the frequency is stable, to realize the stable operation of DG parallel system of microgrid [10]. e frequency droop characteristic curve similar to the traditional generator is selected as the control mode of microsource, that is, the stable frequency and voltage are obtained by P-F droop control and q-u droop control, respectively.…”
Section: Principle Analysis Of the Traditional Droop Control Methodsmentioning
confidence: 99%
“…The fault level can be per-unitized by dividing it by the rated DC power of LCC-HVDC. In this work, CFII is per-unitizing the CF fault level and is described in (24).…”
Section: Improved Immunity To Commutation Failurementioning
confidence: 99%
“…Other publications bring positive results in the performance improvement of the LCC-HVDC when a VSC-HVDC operates in their geographic proximity. Some papers discussed the VSC-HVDC control modes at length, mainly when operating within a multi-infeed system [22][23][24][25], in both transient and steady-state performance.…”
Section: Introductionmentioning
confidence: 99%
“…controlling the DC system can be achieved by controlling the DC voltage [8]. Therefore, with this approach, each non-islanded converter is operated in UdcCtrl and the IFC generates a specific DC voltage reference for the converter, such that the measured active power and DC voltage of the converter lies along a predefined droop curve [4], [13].…”
Section: Multi-vendor With Primary Control Interface (Ifc)mentioning
confidence: 99%