IEEE 36th Conference on Power Electronics Specialists, 2005.
DOI: 10.1109/pesc.2005.1581809
|View full text |Cite
|
Sign up to set email alerts
|

A DQ Synchronous Reference Frame Current Control for Single-Phase Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
43
0
2

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 123 publications
(46 citation statements)
references
References 7 publications
0
43
0
2
Order By: Relevance
“…This current control technique also consists in obtaining the voltage reference (var*) from a PI applied to the grid current error, however, this PI is applied in the dq0 referential [8]. Taking into account that the variables are in the dq0 referential, it is possible to obtain zero stead-state error.…”
Section: Proportional-integral In Synchronous Framementioning
confidence: 99%
See 1 more Smart Citation
“…This current control technique also consists in obtaining the voltage reference (var*) from a PI applied to the grid current error, however, this PI is applied in the dq0 referential [8]. Taking into account that the variables are in the dq0 referential, it is possible to obtain zero stead-state error.…”
Section: Proportional-integral In Synchronous Framementioning
confidence: 99%
“…On the other hand, the most common digital current techniques are: digital PI in stationary frame, digital PI in synchronous frame, and feedforward [8,9,10]. More recently, sliding mode and predictive have gained more importance for power electronics converters (e.g., active rectifiers) [11,12,13].…”
Section: Introductionmentioning
confidence: 99%
“…In other words, the scaling error does not cause the distortion in the estimated grid angle and estimated grid frequency but affects the estimated grid voltage amplitude related to the synchronous q-axis voltage. It only relates to the feedforward term at the output of the current controller [14]. Therefore, this paper is considered to reduce the only dc offset error.…”
Section: D-q Srf Pll In Grid Voltage Measurementmentioning
confidence: 99%
“…However, estimated grid frequency and synchronous dq-axis voltages have the same ripples with the grid frequency. It is very difficult to filter them out using an extremely low bandwidth [14].…”
Section: Introductionmentioning
confidence: 99%
“…In [11] and [12], the DQ transformation methods applied in single-phase grid-tie converters control were proposed and were used to obtain the DC active and reactive power current components from the converters' output current, so that two PI controllers can be used to regulate them without zero steady-state error, respectively. However, both [11] and [12] do not mention these control system transfer functions and stability problems. In this paper, a dual-loop power control strategy for a grid-connected converter with an LCL filter is proposed to implement zero error power control based on PQ theory and its control system transfer function is derived.…”
mentioning
confidence: 99%