A Current Source Converter based Active Power Filter for mitigation of harmonics at the interface of distribution and transmission systems

Abstract: A medium power Current Source Converter (CSC) based Active Power Filter (APF) system is designed and implemented to suppress the amplification of low order harmonics at the Medium Voltage (MV) interface bus between the distribution and transmission systems, owing to the presence of large shunt capacitor banks installed only for reactive power compensation. For this purpose, four CSC based APF units designed at 1.0 kV are operated in parallel, and connected to the 31.5 kV MV bus via a specially designed couplin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
3

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 6 publications
0
9
0
3
Order By: Relevance
“…These types of transformers are excited at the power frequency of 50 or 60 Hz and draw rated kVA mostly as a harmonic load. [2][3][4][5] Nonsinusoidal component in the supply voltage or current (harmonics) have undesirable effects on transformers and causes reduced power quality on the network. 6,7 The losses of a transformer mainly consists of winding (I 2 R) loss, core loss, and other stray losses.…”
Section: Introductionmentioning
confidence: 99%
“…These types of transformers are excited at the power frequency of 50 or 60 Hz and draw rated kVA mostly as a harmonic load. [2][3][4][5] Nonsinusoidal component in the supply voltage or current (harmonics) have undesirable effects on transformers and causes reduced power quality on the network. 6,7 The losses of a transformer mainly consists of winding (I 2 R) loss, core loss, and other stray losses.…”
Section: Introductionmentioning
confidence: 99%
“…[16] [23]. APF with CSC control mechanism for medium voltage to eliminate harmonic well stated by Terciyanli [2]. A VSC platform on STATCOM is also advantageous than CSC based platform [33] [1].…”
Section: Introductionmentioning
confidence: 99%
“…PPF may cause resonance and its filtering characteristic is sensitive to the power system impedance. During the last decade, various active power filter (APF) configurations with their respective control strategies have been proposed [3][4][5][6][7][8][9][10][11]. A novel principle of fundamental magnetic flux compensation (FMFC) is proposed in [12], which is applied as series hybrid APF (SHAPF) [12,13] and controllable reactor [14,15].…”
Section: Introductionmentioning
confidence: 99%