A comparison of older and newer versions of intraoral digital radiography systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

2
44
0
2

Year Published

2010
2010
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(48 citation statements)
references
References 19 publications
2
44
0
2
Order By: Relevance
“…The accuracy of older and newer versions of a CMOS system (Schick CDR/Schick CDR Wireless, Schick Technologies, Long Island City, NY) and a PSP system (Digora FMX/Digora Optime, Soredex) were compared in the detection of proximal carious lesions. 37 The new systems (Digora Optime and Schick CDR Wireless) were found to have significantly higher sensitivities than their predecessors. 37 No significant differences in specificity were found among the Digora FMX, Schick CDR and Schick CDR Wireless systems, all of which had a significantly higher specificity than the Digora Optime (P , 0.02).…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…The accuracy of older and newer versions of a CMOS system (Schick CDR/Schick CDR Wireless, Schick Technologies, Long Island City, NY) and a PSP system (Digora FMX/Digora Optime, Soredex) were compared in the detection of proximal carious lesions. 37 The new systems (Digora Optime and Schick CDR Wireless) were found to have significantly higher sensitivities than their predecessors. 37 No significant differences in specificity were found among the Digora FMX, Schick CDR and Schick CDR Wireless systems, all of which had a significantly higher specificity than the Digora Optime (P , 0.02).…”
Section: Discussionmentioning
confidence: 98%
“…37 The new systems (Digora Optime and Schick CDR Wireless) were found to have significantly higher sensitivities than their predecessors. 37 No significant differences in specificity were found among the Digora FMX, Schick CDR and Schick CDR Wireless systems, all of which had a significantly higher specificity than the Digora Optime (P , 0.02). Fewer false positive diagnoses occurred with the Digora FMX than with the Digora Optime, which also had a lower positive predictive value than that of both CCD systems assessed (P , 0.02).…”
Section: Discussionmentioning
confidence: 98%
“…But Haiter-Neto et al [15] reached a different result. They concluded that NewTom 3G CBCT (with lower spatial resolution than the Accuitomo system) had a lower diagnostic accuracy for detection of caries.…”
Section: Discussionmentioning
confidence: 96%
“…These results vary with the type of CBCT system. The NewTom 3G system had the worst scores for the detection of dentin caries and Accuitomo system had higher sensitivity [15]. The detector used in NewTom 3G system is IIT/CCD (image intensifier tube/charge couple device) that has more pixel noise and image artifacts in comparison with flat panel detector systems [11].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation