2013
DOI: 10.1007/s11340-013-9718-5
|View full text |Cite
|
Sign up to set email alerts
|

A Comparison of Contact Stiffness Measurements Obtained by the Digital Image Correlation and Ultrasound Techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
25
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(28 citation statements)
references
References 41 publications
3
25
0
Order By: Relevance
“…More complicated is the case of the ultrasound transmission through sliding contacts [21,25,[41][42][43][44][45][46], with the pioneering work of Kendall and Tabor [25] being one of the most significant. They used a pin on disc rig under steady sliding and a longitudinal ultrasonic transducer.…”
Section: Ultrasounds and Contactmentioning
confidence: 99%
See 1 more Smart Citation
“…More complicated is the case of the ultrasound transmission through sliding contacts [21,25,[41][42][43][44][45][46], with the pioneering work of Kendall and Tabor [25] being one of the most significant. They used a pin on disc rig under steady sliding and a longitudinal ultrasonic transducer.…”
Section: Ultrasounds and Contactmentioning
confidence: 99%
“…Accurate and non-contacting measurements are possible through laser measurements (see e.g. some of the friction rigs for hysteresis loop measurements [14][15][16][17]) or by using digital image correlation (DIC) [18][19][20][21]. In a recent study [18], the authors have used DIC to monitor the local contact interface of a frictional damper.…”
Section: Introductionmentioning
confidence: 99%
“…Each captured image is compared to the reference image (i.e., the unloaded first image), and displacements for each subset between the current and reference image are calculated within sub-pixel accuracy. The theory and concepts of DIC are comprehensively described in Sutton et al 13 DIC has been applied in fretting experiments to determine frictional properties, such as, hysteresis loops and contact stiffness [14][15][16][17][18] and to measure tangential displacements (relative slip). [19][20][21] DIC has been combined with FEM to calibrate friction coefficient.…”
Section: Introductionmentioning
confidence: 99%
“…One is the experimental approach, where the stiffness can be identified utilizing novel techniques such as ultrasonic assessment [8], digital image correlation [9], modal analysis [10] and virtual fields method [11]. The other approach is to build the theoretical contact model and derive the contact stiffness further.…”
Section: Introductionmentioning
confidence: 99%