2017
DOI: 10.1016/j.icheatmasstransfer.2017.09.009
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study on the performances of different shell-and-tube type latent heat thermal energy storage units including the effects of natural convection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
24
0
5

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 66 publications
(29 citation statements)
references
References 22 publications
0
24
0
5
Order By: Relevance
“…Double-tube heat exchangers (DTHXs) consist of two usually concentric tubes, which create two regions: The inner tube area, and the annulus area between the inner and the outer tube. Depending on which region a PCM and an HTF are located, there are two possible DTHX models: Pipe model and tube model [77,78], which are shown in Figure 5. Han et al [78] showed that the melting time of the PCM in the horizontal cylinder model DTHX was lower by 23.5% compared to the pipe model if the PCM mass and heat transfer surface area was equal in each case.…”
Section: Double-tube Heat Exchangersmentioning
confidence: 99%
See 2 more Smart Citations
“…Double-tube heat exchangers (DTHXs) consist of two usually concentric tubes, which create two regions: The inner tube area, and the annulus area between the inner and the outer tube. Depending on which region a PCM and an HTF are located, there are two possible DTHX models: Pipe model and tube model [77,78], which are shown in Figure 5. Han et al [78] showed that the melting time of the PCM in the horizontal cylinder model DTHX was lower by 23.5% compared to the pipe model if the PCM mass and heat transfer surface area was equal in each case.…”
Section: Double-tube Heat Exchangersmentioning
confidence: 99%
“…Depending on which region a PCM and an HTF are located, there are two possible DTHX models: Pipe model and tube model [77,78], which are shown in Figure 5. Han et al [78] showed that the melting time of the PCM in the horizontal cylinder model DTHX was lower by 23.5% compared to the pipe model if the PCM mass and heat transfer surface area was equal in each case. A similar result was reported by Mahdi et al [79], who found that the melting time of the PCM was 43 and 18 min for pipe and cylinder model, respectively.…”
Section: Double-tube Heat Exchangersmentioning
confidence: 99%
See 1 more Smart Citation
“…Ebenfalls ist das Prinzip des indirekten Kontakts bereits bekannt. In , wird der Wärmeübergang an einem zylinderförmigen Rohr untersucht, das von Wärmeträgermedium durchflossen und von PCM umgeben ist. In wird als Wärmeträgermedium eine flüssige Salzschmelze und als Speichermedium werden zehn unterschiedliche Mischungen aus Salzen mit Schmelztemperaturen oberhalb 400 °C verwendet.…”
Section: Introductionunclassified
“…In wird als Wärmeträgermedium eine flüssige Salzschmelze und als Speichermedium werden zehn unterschiedliche Mischungen aus Salzen mit Schmelztemperaturen oberhalb 400 °C verwendet. In wird als Wärmeträgermedium Luft und als Speichermedium eine eutektische Mischung aus Kaliumnitrat und Natriumnitrat verwendet. In diesen Untersuchungen dienen die Messdaten als Grundlage für Simulationen, um den Schmelzprozess bzw.…”
Section: Introductionunclassified