2015
DOI: 10.1016/j.enbuild.2015.01.045
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study of district and individual energy systems providing electrical-based heating, cooling, and domestic hot water to a low-energy use residential community

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 15 publications
1
10
0
Order By: Relevance
“…), although some varied this value [18][19]74,[79][80][86][87][89][90][91][92][93][94]. In addition to assigning a setpoint temperature for heating periods, a number of studies also defined a setback temperature for non-heating periods [73,[75][76]81,[86][87][88][89][90][91][92][93][94][95]. In these cases, the heating will still come on during non-heating periods (normally unoccupied times or at night) if the internal temperature of the building falls below the setback temperature.…”
Section: Modelling Household Space Heating Preferencesmentioning
confidence: 99%
See 1 more Smart Citation
“…), although some varied this value [18][19]74,[79][80][86][87][89][90][91][92][93][94]. In addition to assigning a setpoint temperature for heating periods, a number of studies also defined a setback temperature for non-heating periods [73,[75][76]81,[86][87][88][89][90][91][92][93][94][95]. In these cases, the heating will still come on during non-heating periods (normally unoccupied times or at night) if the internal temperature of the building falls below the setback temperature.…”
Section: Modelling Household Space Heating Preferencesmentioning
confidence: 99%
“…In relation to the heating periods used, in general, it was evident that studies defined the heating period according to the dwelling's expected occupation hours [18][19][73][74][81][82]86,[88][89][90][91][92][93][94]. This is based on the assumption that occupants do not heat their homes when they are not at home.…”
Section: Modelling Household Space Heating Preferencesmentioning
confidence: 99%
“…The net energy supply cost consists of the levelized fixed or capital costs of the system, the feedstock and fuel supply costs, and all operating and maintenance (O&M) costs, all resolved to a uniform cost of energy considering the time value of money. Capital and O&M costs in general are subject to economies of scale and hence influenced by the size of the units included in the system [60]. Feedstock and O&M costs assumed not to be subject to economies of scale although in practice pricing may depend on supply quantities.…”
Section: Objective Functionmentioning
confidence: 99%
“…To compare the economic performances of the five substations, the integrated cost of energy delivered for unit DHW preparation was calculated based on the results of the individual models: The method for calculating the levelized cost is well described in [15], adapting to the specific cases in this study, the levelized cost of different DHW supply methods can be calculated as: The capital recovery factor can be calculated as:…”
Section: Levelized Costs For Dhw Preparationmentioning
confidence: 99%