2019
DOI: 10.1016/j.msec.2019.109751
|View full text |Cite
|
Sign up to set email alerts
|

A bioresorbable biomaterial carrier and passive stabilization device to improve heart function post-myocardial infarction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 26 publications
(24 citation statements)
references
References 86 publications
0
22
0
Order By: Relevance
“…Slides were imaged using Ocularâ2.0 Imaging Software on an Olympus BX41 Microscope with Olympus U-AN360P analyzer under a 20x objective lens. Quantification of the collagen content was performed using a previously reported technique (58,59). For immunohistochemical analysis, primary antibodies of CD31 (ab28364, Abcam) (1:200), CD68 (MCA341, Bio Rad) (1:300) and α-SMA (ab5694, Abcam) (1:100) were incubated for 1 hour at 37 °C.…”
Section: Microct Histological and Immunohistochemical Analysismentioning
confidence: 99%
“…Slides were imaged using Ocularâ2.0 Imaging Software on an Olympus BX41 Microscope with Olympus U-AN360P analyzer under a 20x objective lens. Quantification of the collagen content was performed using a previously reported technique (58,59). For immunohistochemical analysis, primary antibodies of CD31 (ab28364, Abcam) (1:200), CD68 (MCA341, Bio Rad) (1:300) and α-SMA (ab5694, Abcam) (1:100) were incubated for 1 hour at 37 °C.…”
Section: Microct Histological and Immunohistochemical Analysismentioning
confidence: 99%
“…Resorbable PUs, owing to their tunable mechanical properties and easy complexing with other materials, have been deployed for a variety of applications in vivo to determine basic compatibility for soft tissue repair, 53,155,156 cartilage and bone repair, 157,158 cardiac tissue engineering 159 and wound healing. 160 The studies were conducted using mouse, rat, rabbit and pig models, and spanned observation periods ranging between 2 and 16 weeks.…”
Section: Discussionmentioning
confidence: 99%
“…As a result, much effort is being made to engineer a delivery approach which considers material properties while being minimally invasive. One such example is the novel epicardial carrier device namely Surface Prone EpicArdial Delivery System (SPREADS) 166 designed by Dolan et al The device consists of 2 layers: an outer porous foam layer and an electrospun permeable inner layer. The middle part of the foam formed a bulge structure which contained the hydrogel.…”
Section: Injectability Of Hydrogelsmentioning
confidence: 99%