2020
DOI: 10.1177/1591019920908205
|View full text |Cite
|
Sign up to set email alerts
|

2D parametric contrast time-density analysis for the prediction of complete aneurysm occlusion at six months’ post-flow diversion stent

Abstract: Objective Indications for the treatment of cerebral aneurysms with flow diversion stents are expanding. The current aneurysm occlusion rate at six months ranges between 60 and 80%. Predictability of complete vs. partial aneurysm occlusion is poorly defined. Here, we evaluate the angiographic contrast time-density as a predictor of aneurysm occlusion rate at six months’ post-flow diversion stents. Methods P… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 26 publications
1
6
0
Order By: Relevance
“…Hussein et al also observed increased intra-aneurysmal flow changes after FD treatment in their small cases study. 20 The iFlow TDCs reported in their publication were comparable to those from our study. In contrast to our study, the observed flow changes were not associated with an aneurysm growth, but with the possibility of complete occlusion of the treated aneurysms.…”
Section: Discussionsupporting
confidence: 86%
See 3 more Smart Citations
“…Hussein et al also observed increased intra-aneurysmal flow changes after FD treatment in their small cases study. 20 The iFlow TDCs reported in their publication were comparable to those from our study. In contrast to our study, the observed flow changes were not associated with an aneurysm growth, but with the possibility of complete occlusion of the treated aneurysms.…”
Section: Discussionsupporting
confidence: 86%
“…The literature shows that hemodynamic analysis of treated cerebral aneurysms using iFlow remains a heterogeneous and highly user-dependent method. 19,20,39,40 The parameters assessed in this study are just one of the many ways to analyze such data, so that a direct comparison of our results with similar studies seems to be difficult. In addition, DSA acquisition was performed by manual injection of a contrast agent rather than mechanically using an injector as this is our clinical standard.…”
Section: Limitationsmentioning
confidence: 99%
See 2 more Smart Citations
“…Hemodynamic analysis of cerebral aneurysms using iFlow remains a heterogeneous method. 13 , 15 , 25 The parameters assessed in this study are just one of the many ways to analyze such data, which makes a direct comparison of our results with similar studies difficult. Additionally, the DSA acquisition was performed by manual injection of a contrast agent instead of mechanical injection, as this is our clinical standard.…”
Section: Discussionmentioning
confidence: 99%