Objective Indications for the treatment of cerebral aneurysms with flow diversion stents are expanding. The current aneurysm occlusion rate at six months ranges between 60 and 80%. Predictability of complete vs. partial aneurysm occlusion is poorly defined. Here, we evaluate the angiographic contrast time-density as a predictor of aneurysm occlusion rate at six months’ post-flow diversion stents. Methods Patients with unruptured cerebral aneurysms proximal to the internal carotid artery terminus treated with single flow diversion stents were included. 2D parametric parenchymal blood flow software (Siemens-Healthineers, Forchheim, Germany) was used to calculate contrast time-density within the aneurysm and in the proximal adjacent internal carotid artery. The area under the curve ratio between the two regions of interests was assessed at baseline and after flow diversion stents deployment. The area under the curve ratio between completely vs. partially occluded aneurysms at six months’ follow-up was compared. Results Thirty patients with 31 aneurysms were included. Mean aneurysm diameter was 8 mm (range 2–28 mm). Complete occlusion was obtained in 19 aneurysms. Younger patients ( P = 0.006) and smaller aneurysms ( P = 0.046) presented higher chance of complete obliteration. Incomplete occlusion of the aneurysm was more likely if the area under the curve contrast time-density ratio showed absolute ( P = 0.001) and relative percentage ( P = 0.001) decrease after flow diversion stents deployment. Area under ROC curve was 0.85. Conclusion Negative change in the area under the curve ratio indicates less contrast stagnation in the aneurysm and lower chance of occlusion. These data provide a real-time analysis after aneurysm treatment. If validated in larger datasets, this can prompt input to the surgeon to place a second flow diversion stents.
Introduction
To test the association of vascular health (VH) across young adulthood with midlife dynamic cerebral autoregulation (dCA), gait, and cognition; and to test whether dCA is a modifying factor.
Methods
We studied 196 participants from the Coronary Artery Risk Development in Young Adults cohort who were followed over 30 years. VH was assessed at each visit according to American Heart Association recommendations. At year 30, dCA was measured using transcranial Doppler ultrasound and several gait and cognitive domains were assessed.
Results
Worse VH from baseline through year 7, but not at year 30, was associated with less efficient dCA (all P < .05). Worse VH at all visits was associated with slower gait speed, and at year 7 with worse executive and global cognition (all P < .05). The association of baseline VH and midlife gait, but not cognition, was moderated by dCA (interaction P < .05).
Conclusions
VH as early as young adulthood may influence midlife brain health, and dCA may modify this relationship.
Conclusion The R 4 Q family of catheters incorporates novel technology for CA. This series demonstrates a high FPE and similar rates of SR compared with published data using other aspiration catheters. Further prospective studies of this technology are planned to evaluate its clinical efficacy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.