2016
DOI: 10.1007/s00216-016-9822-3
|View full text |Cite
|
Sign up to set email alerts
|

An interface for online coupling capillary electrophoresis to dielectric barrier discharge ionization mass spectrometry

Abstract: The online combination of capillary electrophoresis (CE) with mass spectrometry (MS) has long been desired for the capability of direct and simultaneous separation and detection with high efficiency, accuracy, and throughput. In this work, a novel CE-MS interface was developed, using dielectric barrier discharge ionization (DBDI). The interface employed a spray tip with a coaxial three-layer structure, into which the CE sample solution, the sheath liquid, and the nebulizing gas were introduced. The spray tip w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 19 publications
1
7
0
Order By: Relevance
“…The LOD ( S / N = 3) for analysis of l -alanine was calculated to be 0.84 pmol, which is lower than the LOD obtained from volume DBDI (3.5 pmol) . Also, the LOD for metronidazole was determined to be 0.18 pmol (also expressed as 0.09 μmol/L), which is lower than the LOD (0.15 mmol/L) for DBDI . These results demonstrate that SDDBDI-MS with the advantage of high-efficiency ion transmission is a very sensitive method.…”
Section: Resultsmentioning
confidence: 63%
See 1 more Smart Citation
“…The LOD ( S / N = 3) for analysis of l -alanine was calculated to be 0.84 pmol, which is lower than the LOD obtained from volume DBDI (3.5 pmol) . Also, the LOD for metronidazole was determined to be 0.18 pmol (also expressed as 0.09 μmol/L), which is lower than the LOD (0.15 mmol/L) for DBDI . These results demonstrate that SDDBDI-MS with the advantage of high-efficiency ion transmission is a very sensitive method.…”
Section: Resultsmentioning
confidence: 63%
“…19 Also, the LOD for metronidazole was determined to be 0.18 pmol (also expressed as 0.09 μmol/L), which is lower than the LOD (0.15 mmol/L) for DBDI. 27 These results demonstrate that SDDBDI-MS with the advantage of highefficiency ion transmission is a very sensitive method.…”
Section: ■ Results and Discussionmentioning
confidence: 78%
“…Zhang et al. developed a CE‐MS interface based on dielectric barrier discharge ionization, separating a mixture of metronidazole and acetaminophen solutions in a proof‐of‐concept study .…”
Section: Instrumentation Interfacing Methodologymentioning
confidence: 99%
“…By a similar set up, CE was also coupled to DBDI-MS recently. 52 A sheathless coupling of CE with MS was realized by an ambient ion source, miniFAPA. 53 The outlet of the CE capillary coated with silver paint was inserted into a T-junction, inside which a nebulizer gas was used to vaporize the effluent of CE.…”
Section: Capillary Electrophoresismentioning
confidence: 99%