2016
DOI: 10.1016/j.ejpb.2016.01.001
|View full text |Cite
|
Sign up to set email alerts
|

Phase-0/phase-I study of dye-loaded lipid nanoparticles for near-infrared fluorescence imaging in healthy dogs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 23 publications
(20 citation statements)
references
References 26 publications
0
20
0
Order By: Relevance
“…Given that ICG is an amphiphilic dye, it can be loaded both inside the lipid core and at the interface of lipid NPs. The pharmacologic and toxicological characteristics of ICG-loaded lipid NPs have been intensively investigated in Beagle dogs 12 . After systematic administration, plasma fluorescence continuously decreased, whereas fluorescence signals mainly occurred in the liver and to a lesser extent in the steroid-rich organs such as adrenal and ovaries, intestines, kidneys, and lymph nodes.…”
Section: In Vivo Biodistribution Of Icg Npsmentioning
confidence: 99%
“…Given that ICG is an amphiphilic dye, it can be loaded both inside the lipid core and at the interface of lipid NPs. The pharmacologic and toxicological characteristics of ICG-loaded lipid NPs have been intensively investigated in Beagle dogs 12 . After systematic administration, plasma fluorescence continuously decreased, whereas fluorescence signals mainly occurred in the liver and to a lesser extent in the steroid-rich organs such as adrenal and ovaries, intestines, kidneys, and lymph nodes.…”
Section: In Vivo Biodistribution Of Icg Npsmentioning
confidence: 99%
“…As lipid nanoparticles are considered as carriers without imaging ability, the lowest amount is injected in the body, the best safety is expected (or the undesired effects are limited). Then, the formulation composed of 91 dyes/particle was selected for further preclinical studies (Cabon et al, 2016;Sayag et al, 2016).…”
Section: Applicability Of the Validated Hplc-fld Method: Optimizationmentioning
confidence: 99%
“…Studies in mice have demonstrated that LipImage®815 displays prolonged circulation within the bloodstream and preferential accumulation within tumors; facilitating fluorescent imaging over 22 days after injection (Jacquart et al, 2013). The toxicity and biodistribution of LipImage®815 have been rapidly investigated in clinical trials (Phase 0/I) on healthy beagle dogs (Sayag et al, 2016). Recently, the potential of this agent as an in vivo NIR nanotracer has been evaluated for intraoperative fluorescence imaging in the surgical excision of malignant masses in dogs (Cabon et al, 2016).…”
Section: Introductionmentioning
confidence: 99%
“…Real-time fluorescence imaging was performed using the compact and portable 2D fluorescence reflectance imaging devices, Fluobeam ® 700 or Fluobeam ® 800, according to the Angiostamp™ labeling. The Fluobeam ® 800 device was used with a dedicated single-use sterile cover bearing an optical window, compatible with NIR fluorescence measurements and with the aseptic conditions of the operating room as described previously by Cabon et al[ 44 , 45 ].…”
Section: Methodsmentioning
confidence: 99%