2017
DOI: 10.1016/j.ijms.2016.12.003
|View full text |Cite
|
Sign up to set email alerts
|

18-Crown-6 spiking in direct infusion ESI–MS analysis of complex mixtures: “One ion per analyte” relationship facilitating ion assignments and eliminating isobaric interferences

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
3

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 26 publications
0
3
0
3
Order By: Relevance
“…A very interesting observation comes from the formal charge that the anthocyanidins have and result on the molecular ion M + observation on mass spectra. Usually during electrospray (ESI) experiments, protonated [M + H] + , sodiated [M + Na] + , potassiated [M + K] + , or other adducts are analyzed …”
Section: Resultsmentioning
confidence: 99%
“…A very interesting observation comes from the formal charge that the anthocyanidins have and result on the molecular ion M + observation on mass spectra. Usually during electrospray (ESI) experiments, protonated [M + H] + , sodiated [M + Na] + , potassiated [M + K] + , or other adducts are analyzed …”
Section: Resultsmentioning
confidence: 99%
“…To determine the TAG profile, a stock solution was prepared by solubilizing 25 μL of calabura oil extract (SH30 and SH60) in 10 mL of MeOH and sonicating for 10 min. Then, this stock solution was diluted using 50 μL of the solution, together with 1950 μL of a carrier solution, which was prepared with 50 mL of MeOH, 0.1% (v/v) trifluoroacetic acid (TFA) and 0.034 mg mL −1 crown ether (18‐crown‐6) 22 …”
Section: Methodsmentioning
confidence: 99%
“…Then, this stock solution was diluted using 50 μL of the solution, together with 1950 μL of a carrier solution, which was prepared with 50 mL of MeOH, 0.1% (v/v) trifluoroacetic acid (TFA) and 0.034 mg mL −1 crown ether (18-crown-6). 22 All samples were prepared in Eppendorf flasks of 2 mL, then homogenized in a tube shaker and injected into the mass spectrometer.…”
Section: Composition Of Extracts Direct Injection In Esi-ms For Analy...mentioning
confidence: 99%
“…A ESI é considerada branda, o que simplifica o espectro de massas de misturas complexas em comparação com técnicas de ionização mais fortes, o que tornou comum o uso desse tipo de ionização em análises diretas de misturas sem separação cromatográfica (TONIN et al, 2017). Uma alternativa para resolver essa dificuldade é sequestrar da solução os principais cátions metálicos.…”
Section: Caracterização De óLeos Vegetaisunclassified
“…Uma alternativa para resolver essa dificuldade é sequestrar da solução os principais cátions metálicos. Éteres coroa podem ser utilizados com esse propósito, uma vez que são conhecidos por serem sequestradores eficientes dos íons Na + e K + (TONIN et al, 2017).…”
Section: Caracterização De óLeos Vegetaisunclassified